Quantitation of serum free light chains.
نویسندگان
چکیده
under usual artificial light conditions, and storage of unproc-essed whole blood without antico-agulants at room temperature on the bench. Additionally, we tested the effect of multiple freeze-thaw cycles. 25(OH)–vitamin D 3 measurements were performed on a Cobas E601 an-alyzer (Roche), using the vitamin D 3 (25-OH) assay as recommended by the manufacturer. Samples from each storage experiment were analyzed in 1 run after being stored in the freezer at Ϫ20 °C. The interassay CVs for pooled serum analyses (frozen aliquots) were 6.9% at 25.5 nmol/L 25(OH)–vitamin D 3 and 3.2% at 72.5 nmol/L. For the Roche Bone Control we found CVs of 4.8% at 49.8 nmol/L 25(OH)–vitamin D 3 and 4.0% at 97.8 nmol/L. Exposure to 4 freeze-thawing cycles had no important effect on 25(OH)–vitamin D 3 concentrations ; the values for the mean of 8 samples increased 2.6% from the initial values. This small increase can be attributed to evaporation or freeze-drying processes, but we believe there is also a small positive effect due to increased turbidity of the samples after freeze-thawing cycles. A 4.0% decrease in the mean concentration was seen following storage at Ϫ20 °C for up to 2 months. Mean 25(OH)–vitamin D 3 concentrations (n ϭ 8) during storage under these common laboratory conditions are presented in Fig. 1. A mean decrease of 2.3% was noted after 72 h storage of whole blood on the bench at room temperature, and a mean decrease of 3.4% after 24 h and 8.5% after 7 days storage of serum on the bench in daylight. Mean decreases of 4.5% after 3 days and 8.1% after 7 days storage of serum in the dark at room temperature were noted, whereas a mean decrease of 1.8% was observed after 7-day storage of serum in the refrigerator. We found the concentrations of 25(OH)–vitamin D 3 in its natural state bound to vitamin D– binding protein to be very stable at room temperature, even for un-processed whole blood. For either processed or unprocessed samples, delays of several hours before analysis had negligible effects. Even " forgotten " samples or samples received in an unfrozen state appear to be suitable for analysis, because the decreases noted after 3 days under usual laboratory conditions at room temperature were less than the analytical interassay precision. There appears to be no need for serum to be frozen for transport, and whole blood might even be the specimen of …
منابع مشابه
Serum Free Light-chain Assay for the Diagnosis, Management, and Prognosis of Multiple Myeloma
In recent decades, new serum biomarkers have been developed for routine laboratory practice, such as assaying serum free light chains and more recently, assaying immunoglobulin heavy and light chain isotypes (Hevylite). In this work, we highlight the interest of new biomarkers (Hevylite Test) in the management of monoclonal gammopathies because of the technical advantages it confers and the se...
متن کاملDevelopment and characterization of polyclonal antibody against human kappa light chain in rabbit
Polyclonal antibodies against kappa light chain are used to diagnose diseases producing free light chain. The kappa and lambda light chains are products of immunoglobulin synthesis and released into the circulation in minor amounts such as serum, cerebrospinal fluid, urine and synovial fluid in normal condition. The purpose of this study was the production and purification of polyclonal immunog...
متن کاملAssessment of Intrathecal Free Light Chain Synthesis: Comparison of Different Quantitative Methods with the Detection of Oligoclonal Free Light Chains by Isoelectric Focusing and Affinity-Mediated Immunoblotting
OBJECTIVES We aimed to compare various methods for free light chain (fLC) quantitation in cerebrospinal fluid (CSF) and serum and to determine whether quantitative CSF measurements could reliably predict intrathecal fLC synthesis. In addition, we wished to determine the relationship between free kappa and free lambda light chain concentrations in CSF and serum in various disease groups. METHO...
متن کاملUtility of serum Fatty Acid concentrations as a marker for acute myocardial infarction and their potential role in the formation of ischemia-modified albumin: a pilot study.
1. Pattenden RJ, Rogers SY, Wenham PR. Serum free light chains; the need to establish local reference intervals. Ann Clin Biochem 2007; 44:512–5. 2. Piehler AP, Gulbrandsen N, Kierulf P, Urdal P. Quantitation of serum free light chains in combination with protein electrophoresis and clinical information for diagnosing multiple myeloma in a general hospital population. Clin Chem 2008;54: 1823–30...
متن کاملQuantitative measurement of immunoglobulins and free light chains using mass spectrometry.
Serum free light chain (sFLC) assays are well established in the diagnosis and monitoring of plasma cell disorders. However, current FLC immunoassays are subject to several analytical issues, which results in a lack of harmonized results. To facilitate sFLC standardization, we investigated the strengths and limitations of mass spectrometry as a novel technological platform for sFLC quantificati...
متن کاملQuantitative serum free light chain assay in the diagnostic evaluation of AL amyloidosis.
We compared a new serum immunoassay for quantitation of serum free light chains (FLC) with the conventional tests for clonal immunoglobulin production: bone marrow immunohistochemistry, serum immunofixation electrophoresis, and urine immunofixation electrophoresis. Serum samples from 169 patients with AL amyloidosis and 20 controls were examined. Elevated levels of kappa-FLC and lambda-FLC were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 55 8 شماره
صفحات -
تاریخ انتشار 2009