Distal embolization of hydrophilic-coating material from coronary guidewires after percutaneous coronary interventions.
نویسندگان
چکیده
BACKGROUND Coronary guidewires are indispensable during percutaneous coronary interventions. Nowadays, most guidewires have hydrophilic coatings to improve their trackability, allowing easy lesion passage and facilitating balloon and stent positioning. Recent reports, however, have raised concerns about detachment and subsequent embolization of these hydrophilic coatings. METHODS AND RESULTS We have retrospectively reviewed the histological samples of the myocardium, obtained during autopsies in the period 2009 to 2013, from all patients who had a history of percutaneous coronary interventions (n=40). Foreign material was observed in the distal myocardium in 4 patients (10%). Furthermore, we have reviewed 205 thrombus specimens which were obtained during thrombus aspiration in the setting of primary percutaneous coronary interventions in the period 2005 to 2009. In 45% of the cases, foreign material was observed within the thrombus. Finally, we have examined the histopathologic appearance of hydrophilic-guidewire coating material ex vivo by embedding the coating in placenta specimen and cut and stain it in exactly the same manner as the myocardium and thrombus specimen. The histopathologic appearance of the hydrophilic coating ex vivo was identical to the foreign material found in vivo. CONCLUSIONS Distal embolization of hydrophilic-coating material was observed in 10% of the patients who had a history of percutaneous coronary interventions. Hydrophilic-coating material was found in 45% of coronary thrombus specimen obtained during thrombus aspiration. These findings suggest that detachment and distal embolization of hydrophilic-coating material from coronary guidewires occur more often than the sparse literature on this topic suggests.
منابع مشابه
Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection.
BACKGROUND Although distal embolization and the "no-reflow" phenomenon are well described in saphenous vein graft (SVG) interventions, the frequency, magnitude, and characterization of embolized debris have not been evaluated in routine coronary interventions. A unique embolus protection device described herein provides a means of containing and retrieving plaque material dislodged during percu...
متن کاملPeeled Guidewire Coating with Debulked Plaque Obtained by Directional Coronary Atherectomy
Percutaneous directional coronary atherectomy (DCA) is a plaque debulking method performed in Japan, and recently a renewed DCA device has been launched. We present a case with a tight left anterior descending lesion undergoing percutaneous coronary intervention with application of DCA. After several sessions of DCA, white plaques accompanied by green, stringed materials were obtained from the ...
متن کاملCollagen embolization for the successful treatment of a distal coronary artery perforation.
A 42-year old man suffered a coronary artery perforation in the right coronary artery secondary to a hydrophilic guidewire. We describe for the first time the use of collagen embolization to successfully treat this complication.
متن کاملNo-Reflow Phoenomenon by Intracoronary Thrombus in Acute Myocardial Infarction
Recently, percutaneous coronary intervention has been the treatment of choice in most acute myocardial infarction cases. Although the results of percutaneous coronary interventions have ben good, the no-reflow phenomenon and distal embolization of intracoronary thrombus are still major problems even after successful interventions. In this article, we will briefly review the deleterious effects ...
متن کاملAssociation of target lesion characteristics evaluated by coronary computed tomography angiography and plaque debris distal embolization during percutaneous coronary intervention.
BACKGROUND The slow-flow or no re-flow phenomenon has been associated with distal embolization, especially of plaque debris, and with unfavorable clinical outcomes. Therefore, we examined the association between the coronary computed tomography angiography (CCTA) findings of the target lesion and distal embolization during percutaneous coronary intervention (PCI). METHODS AND RESULTS: Consecuti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 8 2 شماره
صفحات -
تاریخ انتشار 2015