Securement of the Indwelling Urinary Catheter: A Prevalence Study.

نویسندگان

  • Yvonne Appah
  • Kathleen F Hunter
  • Katherine N Moore
چکیده

PURPOSE The aims of this study were 4-fold: (1) to examine the proportion of indwelling urinary catheters that were secured in an acute care setting; (2) to determine the proportion of secured catheters that were secured correctly; (3) to examine the association of catheter securement with type of unit, age, sex, and location of insertion; and (4) to determine the proportion of units with catheter securement products available on the unit. DESIGN Descriptive prevalence study. SUBJECTS AND SETTING All medical and surgical units (n = 21) were surveyed for inpatients with indwelling urinary catheters in 1 urban tertiary care hospital in Western Canada. Critical care and pediatric units were excluded. METHODS During a 6-hour period, 6 RNs data collectors recorded presence and accuracy of catheter securement, area where the participant was catheterized, and availability of securement products on unit. Data were collected using a data form designed for the study. RESULTS Seventy-two of 370 inpatients had indwelling catheters on the day of the study. Of these, 61% (44/72) participated. The overall prevalence of catheter securement was 18% (8/44). Seven of the 8 secured catheters were secured correctly. The primary method of securement was a commercial adhesive device (6/8; 75%). Securement products were stocked on 47% of medicine units and 92% of surgical units. CONCLUSION Findings are consistent with other studies and indicate that catheter securement practices are inadequate despite several guidelines published on catheter care.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe indwelling urinary catheter-associated urethral erosion in four elderly men.

Medical devices often are overlooked as a potential cause of pressure ulcers. Indwelling urinary catheters have been described as a cause of urethral erosion. In men, the resultant partial-thickness or full-thickness wound can involve a small area of the glans penis or cleave the glans or penile shaft, requiring reconstructive surgery or urinary diversion. During a 3-month period, four elderly...

متن کامل

Prevalence and Microbiological Profile of Catheter Associated Urinary Tract Infections: A Case Study in Secondary Care Hospital

Background and Objectives: Healthcare-associated infections is a major health care concern posing potentially serious negative impact on patient safety and outcome. In this paper, we report this microbiological profile and the prevalence of Catheter Associated Urinary Tract Infections (CAUTIs). Methods: This was a prospective observational study for...

متن کامل

Spinal anesthesia: should everyone receive a urinary catheter?: a randomized, prospective study of patients undergoing total hip arthroplasty.

BACKGROUND The objective of this randomized prospective study was to determine whether a urinary catheter is necessary for all patients undergoing total hip arthroplasty under spinal anesthesia. METHODS Consecutive patients undergoing total hip arthroplasty under spinal anesthesia were randomized to treatment with or without insertion of an indwelling urinary catheter. All patients received s...

متن کامل

Current status of indwelling urinary catheter utilization and catheter-associated urinary tract infection throughout hospital wards in Korea: A multicenter prospective observational study

To evaluate the frequency and appropriateness of indwelling urinary catheters (IUC) use and the incidence of catheter-associated urinary tract infections (CA-UTI), and explore the risk factors for CA-UTI in hospitals as a whole, we conducted a study. This study was divided into two parts; a point-prevalence study on Dec 12th 2012 and a prospective cohort study from Dec 13th 2012 to Jan 9th 2013...

متن کامل

A prospective trial on a new sutureless securement device for central venous catheters.

To the Editor, We share our experience with a new catheter securement device called the SecurAcath" (Interrad Medical, Plymouth, MN, USA). It utilizes small folding subcutaneous nitinol tines that anchor an intravenous catheter at the insertion site (Figure, panels A and B). The anchor is designed to be atraumatic, and it is magnetic resonance imaging compatible. An instructional video provided...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2016