Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology.

نویسندگان

  • Johannes Tran-Gia
  • Susanne Schlögl
  • Michael Lassmann
چکیده

Currently, the validation of multimodal quantitative imaging and absorbed dose measurements is impeded by the lack of suitable, commercially available anthropomorphic phantoms of variable sizes and shapes. To demonstrate the potential of 3-dimensional (3D) printing techniques for quantitative SPECT/CT imaging, a set of kidney dosimetry phantoms and their spherical counterparts was designed and manufactured with a fused-deposition-modeling 3D printer. Nuclide-dependent SPECT/CT calibration factors were determined to assess the accuracy of quantitative imaging for internal renal dosimetry. METHODS A set of 4 single-compartment kidney phantoms with filling volumes between 8 and 123 mL was designed on the basis of the outer kidney dimensions provided by MIRD pamphlet 19. After the phantoms had been printed, SPECT/CT acquisitions of 3 radionuclides (99mTc, 177Lu, and 131I) were obtained and calibration constants determined for each radionuclide-volume combination. A set of additionally manufactured spheres matching the kidney volumes was also examined to assess the influence of phantom shape and size on the calibration constants. RESULTS A set of refillable, waterproof, and chemically stable kidneys and spheres was successfully manufactured. Average calibration factors for 99mTc, 177Lu, and 131I were obtained in a large source measured in air. For the largest phantom (122.9 mL), the volumes of interest had to be enlarged by 1.2 mm for 99mTc, 2.5 mm for 177Lu, and 4.9 mm for 131I in all directions to obtain calibration factors comparable to the reference. Although partial-volume effects were observed for decreasing phantom volumes (percentage difference of up to 9.8% for the smallest volume [8.6 mL]), the difference between corresponding sphere-kidney pairs was small (<1.1% for all volumes). CONCLUSION 3D printing is a promising prototyping technique for geometry-specific calibration of SPECT/CT systems. Although the underlying radionuclide and the related collimator have a major influence on the calibration, no relevant differences between kidney-shaped and spherically shaped uniform-activity phantoms were observed. With comparably low costs and submillimeter resolution, 3D printing techniques hold the potential for manufacturing individualized anthropomorphic phantoms in many clinical applications in nuclear medicine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

InRaDoS: An internal radiation dosimetry computer program

Introduction: Internal radiation dosimetry is important from a radiation protection point of view and can help to optimize the radiation dose delivered to the workers, public, and patients. It has a rather simple protocol but needs a large amount of data. Therefore, it is difficult to do on a routine basis. The use of computer programs makes internal radiation dosimetry simpler...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Development of Computed Tomography Head and Body Phantom for Organ Dosimetry

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

متن کامل

Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT

BACKGROUND The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD The phantom de...

متن کامل

Development of Iranian Adult Female Reference Phantom for Internal Dosimetry Calculations

Estimation of organ doses in diagnostic and therapeutic nuclear medicine procedures is an area of particular concern for radiation protection, in all over the world. The stylized computational phantoms have contributed significantly to radiation dosimetry in nuclear medicine; however, their simplified treatment of human anatomy is being criticized. Due to the fact that the ICRP adult reference ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 12  شماره 

صفحات  -

تاریخ انتشار 2016