Defining patient-prosthesis mismatch and its effect on survival in patients with impaired ejection fraction.

نویسندگان

  • David A Cotoni
  • Robert T Palac
  • Lawrence J Dacey
  • Daniel J O'Rourke
چکیده

BACKGROUND How best to define patient-prosthesis mismatch (PPM) continues to be debated. Over time, the indexed effective orifice area has become the most widely used method. However, the clinical relevance of PPM remains controversial. METHODS The indexed geometric orifice area and indexed effective orifice area were calculated for 143 patients having undergone aortic valve replacement with a normal left ventricular function 0.45 or less. Using the indexed geometric orifice area method, PPM was defined as nonsignificant if 1.2 cm(2)/m(2) or greater and as significant if less than 1.2 cm(2)/m(2). Using the indexed effective orifice area method, PPM was considered as nonsignificant if greater than 0.85 cm(2)/m(2), as moderate if greater than 0.65 cm(2)/m(2) and less than or equal to 0.85 cm(2)/m(2), and as severe PPM if 0.65 cm(2)/m(2) or less. RESULTS The number of patients classified as having PPM differed according to the method used to predict its presence (PPM: Effective orifice area method = 72.7%; geometric method = 19.6%). Regardless of the method used to classify PPM there was no significant effect on mortality (adjusted hazard ratio: 2.65 at 1 year, 0.99 at 5 years, 0.92 at 9 years; p = not significant). The postoperative mean transvalvular gradient (17.1 ± 6.5 mm Hg) and left ventricular function (0.50 ± 0.145) improved significantly compared with the preoperative findings. CONCLUSIONS The method used to calculate PPM resulted in significant classification discordance. However, regardless of classification, the presence of PPM did not adversely affect long-term outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Moderate patient-prosthesis mismatch has no independent effect on 30-day mortality after isolated aortic valve replacement].

INTRODUCTION AND OBJECTIVES It is still not clear whether the presence of a moderate patient-prosthesis mismatch after isolated aortic valve replacement can increase 30-day mortality. The aim of this study was to determine whether a moderate mismatch is an independent predictor of early global or cardiac mortality after aortic valve replacement. METHODS The study involved 272 adult patients (...

متن کامل

Patient-prosthesis mismatch after transapical aortic valve implantation.

OBJECTIVES Transcatheter aortic valve implantation (TAVI) has become an important therapeutic option for high-risk patients with severe aortic valve stenosis. Patient-prosthesis mismatch (P-PM) is an important determinant of morbidity and mortality after open aortic valve replacement. The objective of our study was to evaluate P-PM incidence and its impact on survival in a large cohort of patie...

متن کامل

Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction.

OBJECTIVES This study was designed to evaluate the effect of valve prosthesis-patient mismatch (PPM) on late survival after aortic valve replacement (AVR) and to determine if this effect is modulated by patient age, body mass index (BMI), and pre-operative left ventricular (LV) function. BACKGROUND We recently reported that PPM is an independent predictor of operative mortality after AVR, par...

متن کامل

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 2011