Physical basis of the dependence of blood viscosity on tube radius.

نویسنده

  • R H HAYNES
چکیده

HAYNES, ROBERT H. Physical basis of the dependence of blood viscosity on tube radius. Am. J. Physiol. 1g8(6) : I 1g3--1200. 1g6o.-Two theories are applied to measurements of the decrease in apparent viscosity of blood in narrow tubes (FahraeusLindqvist effect). First, the effect may be attributed to the presence of unsheared laminae in the fluid (sigma phenomenon), and it was found that the thickness of such laminae must vary between 3.5 p at 10% hematocrit and 34 p at 807& Alternatively, the effect may be caused by a cell-free marginal zone adjacent to the tube wall, which would have to be 6 p thick at 10% hematocrit and I .5 p at 80%. There is a slight suggestion in the data that the effect may be reversed as the flow rate approaches zero (i.e. the apparent viscosity rises in small tubes). Finally, a method is proposed for calculating the effective diameter of a vascular bed, and it was found to be 55 ~1 for a dog’s hind limb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physical basis of the dependence of blood viscosity on tube radius1

HAYNES, ROBERT H. Physical basis of the dependence of blood viscosity on tube radius. Am. J. Physiol. 1g8(6) : I 1g3--1200. 1g6o.-Two theories are applied to measurements of the decrease in apparent viscosity of blood in narrow tubes (FahraeusLindqvist effect). First, the effect may be attributed to the presence of unsheared laminae in the fluid (sigma phenomenon), and it was found that the thi...

متن کامل

Performance Evaluation of Viscosity Characteristics of Enhanced Preformed Particle Gels (PPGs)

Preformed Particle Gels (PPGs) treatment is one of the most promising solutions to improve conformance control in mature water flooded oil reservoirs. It is very important to be able to evaluate and predict performance of PPGs in porous media. In this paper, we will first introduce new class of enhanced PPGs designed for harsh reservoir conditions (high salinity and temperature) and then pr...

متن کامل

A Mathematical Model for Blood Flow Through Narrow Vessels with Mild-Stenosis (RESEARCH NOTE)

In this paper we examine the effect of mild stenosis on blood flow, in an irregular axisymmetric artery with oscillating pressure gradient. The Herschel-Bulkley fluid model has been utilized for this study. The combined influence of an asymmetric shape and surface irregularities of constriction has been explored in this computational study. An extensive quantitative analysis has been performed ...

متن کامل

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

Blood viscosity in tube flow: dependence on diameter and hematocrit.

Since the original publications by Martini et al. (Dtsch. Arch. Klin. Med. 169: 212-222, 1930) and Fahraeus and Lindqvist (Am. J. Physiol. 96: 562-568, 1931), it has been known that the relative apparent viscosity of blood in tube flow depends on tube diameter. Quantitative descriptions of this effect and of the dependence of blood viscosity on hematocrit in the different diameter tubes are req...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of physiology

دوره 198  شماره 

صفحات  -

تاریخ انتشار 1960