Noninvasive pulsed Doppler echocardiographic detection of the direction of shunt flow in patients with atrial septal defect: usefulness of the right parasternal approach.

نویسندگان

  • S Minagoe
  • C Tei
  • A Kisanuki
  • K Arikawa
  • Y Nakazono
  • H Yoshimura
  • T Kashima
  • H Tanaka
چکیده

Noninvasive pulsed Doppler echocardiography combined with two-dimensional echocardiography by the right parasternal approach was performed to detect the shunt flow through the defect in 31 patients with suspected secundum atrial septal defect (ASD). A defect of the interatrial septum was seen on the two-dimensional echocardiograms of 30 of 31 patients. In all the 30 patients, Doppler signals of shunt flow could be recorded by placing the sample volume in the center of the defect on the two-dimensional echocardiogram. Neither a defect nor Doppler signal indicating shunt flow were demonstrated in any of 15 normal control subjects. Cardiac catheterization indicated significant shunt flow in all the 31 patients with suspected ASD. Doppler signals obtained from the center of the defect showed left-to-right and/or right-to-left shunt flow patterns. The direction of the shunt flow was mainly left to right, with its peak in late systole and atrial systole in 28 of 30 patients; mainly right-to-left flow was present in the remaining two patients, who had Eisenmenger's syndrome. The direction of flow as predicted by the Doppler signal was confirmed by the coincidence of direction of flow as seen on the contrast two-dimensional echocardiogram. In 22 patients for whom the measurement of the pulmonary-to-systemic flow ratio by oximetry was believed to be reasonably accurate, the ratio was fairly well correlated with Doppler-determined left-to-right shunt flow velocity (r = .71, SEE = 6.7 cm/sec).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An echocardiographic study of perimembranous ventricular septal defect with left ventricular to right atrial shunting.

Twenty nine patients with isolated perimembranous ventricular septal defects were investigated by M mode, cross sectional, and pulsed Doppler echocardiography. Tricuspid valve anomalies were present in all six patients with a left ventricular-right atrial shunt but in only six (26%) of 23 patients who had interventricular shunts only. Systolic flutter of the tricuspid valve was shown in five (8...

متن کامل

Shunt Size in Atrial Septal Defect

Two-dimensional echocardiography and pulsed-Doppler studies have not proved to be reliable methods of assessing left-to-right shunt size in atrial septal defect. Doppler color-flow imaging displays the transatrial jet, providing a new dimension with the potential capability of quantifying left-to-right shunt size. Twenty-three patients with atrial septal defect were studied by color-flow imagin...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Cor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report

  Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium  through restrictive opening to the low-pressure, dis...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 71 4  شماره 

صفحات  -

تاریخ انتشار 1985