Investigation of the effect of a disposal endotracheal catheter and metal catheter combination application in inhalation injury patients.
نویسندگان
چکیده
Objective. The aim of this paper was to make an objective evaluation of the scientific nature and effectiveness of a combination application of two catheters by investigating and comparing the effects and the occurrence of complications using a single metal catheter application, a single disposal endotracheal catheter application, and a combination application of these two catheters separately in tracheotomy patients. Method. A study was carried out on 85 patients with a metal catheter from 1990 to 1997, 62 patients with a disposal endotracheal catheter from 1998 to 2002, and 56 patients with an on-vent disposal endotracheal catheter and an off-vent metal catheter from 2003 to November 2008, defined respectively as groups A, B, and C, in order to observe catheter balloon rupture and catheter olisthe during intubation, as also sputum adhesion to the endotracheal catheter wall after application, and to assess the number of cases of patients with airway bleeding, the number of patients with endotracheal catheter blockage, and the time lapse between ventilator withdrawal and extubation. Results. Patients in groups B and C were observed to have balloon rupture; the number of patients with catheter olisthe and airway bleeding was in both cases less than in group A (p < 0.05); and in groups A and C the number of patients with catheter blockage was in both cases less than in group B (p < 0.05) - extubation time was also shorter than in group B, but without statistical significance (p > 0.05). Macroscopic observation found that there was a large amount of sputum adhering to the lumen of the open disposal endotracheal catheter and that the lumen became significantly narrow, while the metal catheter became non-significantly narrow. Conclusion. In inhalation injury patients we found that the effect of the combination application of the disposal endotracheal catheter and the metal catheter was better than that of the single application.
منابع مشابه
بررسی اثر اولتراسوند بر صدمات ایسکمی مغزی در مدل ترومبوآمبولیک سکته مغزی در رت
Background: Ultrasound (US) has been used in neuroprotection after cerebral ischemia however, its use is controversial. Application of US in combination with fibrinolytic agents may improve fibrinolytic effects. In this study the effects of US, alone or in combination with tissue plasminogen activator (tPA), on brain ischemic injury were examined and we studied whether US is protective in the b...
متن کاملThe Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملComparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter
Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...
متن کاملA Comparative Study of the Efficacy of Surfactant Administration through a Thin Intratracheal Catheter and its Administration via an Endotracheal Tube in Neonatal Respiratory Distress Syndrome
Background: The cornerstone of the treatment of respiratory distress syndrome (RDS) is respiratory support and surfactant replacement therapy. The administration of surfactant through a thin intratracheal catheter is one of the methods used to reduce one of the standard technique complications of a surfactant injection (Intubation-Surfactant-Extubation method [INSURE]). The aim of this study wa...
متن کاملPreventing Traumatic Urinary Catheter Insertion Through a Computerized Ordering System: Quasi-experimental Study From a Tertiary Academic Center
Background: Iatrogenic urethral injury is a well-known risk of urinary catheter insertion. Associated morbidities include stricture formation, catheter associated infection, risk for instrumentation, and extended length of stay. Yet, insufficient attention is paid to its prevention. Objective: This study aimed to assess the effectiveness of a computerized...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of burns and fire disasters
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2009