BACKGROUND AND PURPOSE In clinical practice, achieved lengthening of a callotasis zone should be maintained after the external fixator has been removed. The common understanding has been that the regenerated bone may subside. To investigate this, we used high-resolution radiostereometric analysis (RSA) with accurate measurement of the lengthening zone. PATIENTS AND METHODS We assessed the longitudinal subsidence of a callotasis zone after removal of the external fixator in distraction osteogenesis in 16 patients who underwent 17 segmental lengthening operations on the tibia (n = 9) or femur (n = 8). Median lengthening was 32 (6-80) mm. RSA was performed at the end of the consolidation period before the external fixation device was removed, and this was later repeated at a median time of 11 (4-32) weeks after frame removal. RESULTS A minimal median longitudinal change of 0.01 (-0.28 to 0.60) mm across the lengthening zone occurred in uncomplicated cases. INTERPRETATION Our results indicate that no subsidence of clinical interest occurs after external frame removal.
منابع مشابه
Application of locked intramedullary nails in the treatment of complications after distraction osteogenesis.
Distraction osteogenesis (callotasis) has been widely used in patients with limb-length inequality or massive bone defects. This procedure, however, may be associated with a high incidence of physical and psychosocial complications. Callotasis telescoping on a locked intramedullary nail has been used to shorten the period of external fixation. Little attention has been given to the use of locke...
متن کاملComplications associated with bone lengthening of the lower limb by callotasis.
The present study aims to assess the incidence of complications related to bone lengthening procedures and to identify factors that may predict these complications. We retrospectively studied 51 lengthening procedures in 39 patients (mean age 13 years) from 2001 to 2015. A circular external fixator was used in 37 procedures and a monolateral fixator in 14 procedures. Duration of distraction, fi...
متن کاملA Simple and Light Weight External Fixator for Distraction Advancement Manoplasty
BACKGROUND With the growing interest in long bone distraction several types of distractors have been introduced; all have the same principle of an outer structure which acts like a scaffold and the distracting mechanism is a separate device which is mounted on this outer structure. OBJECTIVES We have used a simple and very light weight external fixator we designed and discuss the results of d...
متن کاملLow-intensity pulsed ultrasound accelerates bone maturation in distraction osteogenesis in rabbits.
We investigated the effects of low-intensity pulsed ultrasound on distraction osteogenesis in a rabbit model. Callotasis of the right tibia was performed in 70 male Japanese white rabbits using mini-external fixators. In the first part of the study in 64 animals using normal distraction (waiting period seven days; distraction rate 0.5 mm/12 hours; distraction period ten days), we evaluated the ...
متن کاملLimb salvage using distraction osteogenesis. A classification of the technique.
We report the results of distraction osteogenesis (callotasis) for the reconstruction of extensive defects after the excision of skeletal tumours in the limbs. Bone transport was performed in ten patients (five osteosarcomas and five giant-cell tumours), shortening-distraction in three (two osteosarcomas and one Ewing's sarcoma), and distraction osteogenesis combined with an intramedullary nail...
متن کامل