Noise weighted T2*-IDEAL Reconstruction for Non-uniformly Under-Sampled k-space Acquisitions
نویسندگان
چکیده
C. N. Wiens, S. J. Kisch, C. D. Hines, H. Yu, A. R. Pineda, P. M. Robson, J. H. Brittain, S. B. Reeder, and C. A. McKenzie Department of Physics and Astronomy, University of Western Ontario, London, Ont, Canada, Department of Medical Biophysics, University of Western Ontario, London, Ont, Canada, Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, United States, Applied Science Laboratory, GE Healthcare, Menlo Park, CA, United States, Department of Mathematics, California State University, Fullerton, CA, United States, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States, Applied Science Laboratory, GE Healthcare, Madison, WI, United States, Department of Radiology, University of Wisconsin-Madison, Madison, WI, United States
منابع مشابه
Accelerating PROPELLER-MRI by Means of Under-Sampling and Iterative Image Reconstruction using the Non-Uniform Fast Fourier Transform
Introduction: PROPELLER-MRI is a multi-shot fast spin-echo (FSE) data acquisition technique that is gaining popularity due to its reduced sensitivity to motion and B0 inhomogeneities. However, k-space sampling in PROPELLER is performed on a set of parallel lines forming a blade, which is rotated to cover k-space. This sampling pattern oversamples the central region of k-space, and PROPELLER acq...
متن کاملMulticontrast 3D Structural Imaging to Improve Automatic Brain Extraction and Segmentation
Introduction: Structural neuroimaging studies rely on T1-weighted images to provide gray/white matter contrast for image segmentation. As an initial step in a morphological study, brain extraction is performed to remove from consideration all non-brain tissues. However, some regions lack sufficiently distinctive T1 contrast between brain matter and adjacent soft tissues and bone, making brain e...
متن کاملIncreasing the resolution of diffusion-weighted MRI with distortion compensated orthogonal acquisitions and super-resolution reconstruction
Introduction. Increasing the spatial resolution in diffusion-weighted imaging (DWI) is very challenging with a single shot EPI acquisition. It requires sampling of higher frequencies in k-space, making the acquisition highly demanding on the scanner gradient coils when achieving the spatial encoding. Additionally, reducing the voxel size by a factor α is challenging because it requires α averag...
متن کاملModel-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI.
PURPOSE To develop a model-based reconstruction technique for T2 mapping based on multi-echo spin-echo MRI sequences with highly undersampled Cartesian data encoding. MATERIALS AND METHODS The proposed technique relies on a nonlinear inverse reconstruction algorithm which directly estimates a T2 and spin-density map from a train of undersampled spin echoes. The method is applicable to acquisi...
متن کاملStatistical noise model in GRAPPA-reconstructed images
Noise in Parallel Imaging Parallel MRI (pMRI) techniques extended the applicability of multiple-coil systems by increasing the acquisition rate via subsampled acquisitions of the k-space data. Many reconstruction methods have been proposed in order to suppress the aliasing and underlying artifacts created by the subsampling. Dominant among these are SENSE and GRAPPA. One of the effects in accel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009