Expiratory flow rate, breath hold and anatomic dead space influence electronic nose ability to detect lung cancer

نویسندگان

  • Andras Bikov
  • Marton Hernadi
  • Beata Zita Korosi
  • Laszlo Kunos
  • Gabriella Zsamboki
  • Zoltan Sutto
  • Adam Domonkos Tarnoki
  • David Laszlo Tarnoki
  • Gyorgy Losonczy
  • Ildiko Horvath
چکیده

BACKGROUND Electronic noses are composites of nanosensor arrays. Numerous studies showed their potential to detect lung cancer from breath samples by analysing exhaled volatile compound pattern ("breathprint"). Expiratory flow rate, breath hold and inclusion of anatomic dead space may influence the exhaled levels of some volatile compounds; however it has not been fully addressed how these factors affect electronic nose data. Therefore, the aim of the study was to investigate these effects. METHODS 37 healthy subjects (44 ± 14 years) and 27 patients with lung cancer (60 ± 10 years) participated in the study. After deep inhalation through a volatile organic compound filter, subjects exhaled at two different flow rates (50 ml/sec and 75 ml/sec) into Teflon-coated bags. The effect of breath hold was analysed after 10 seconds of deep inhalation. We also studied the effect of anatomic dead space by excluding this fraction and comparing alveolar air to mixed (alveolar + anatomic dead space) air samples. Exhaled air samples were processed with Cyranose 320 electronic nose. RESULTS Expiratory flow rate, breath hold and the inclusion of anatomic dead space significantly altered "breathprints" in healthy individuals (p < 0.05), but not in lung cancer (p > 0.05). These factors also influenced the discrimination ability of the electronic nose to detect lung cancer significantly. CONCLUSIONS We have shown that expiratory flow, breath hold and dead space influence exhaled volatile compound pattern assessed with electronic nose. These findings suggest critical methodological recommendations to standardise sample collections for electronic nose measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of breath holding at total lung capacity on maximal expiratory flow measurements.

1. Forced exhalations performed from volumes below total lung capacity, so-called partial expiratory flow-volume curves, are suggested to be more sensitive in detecting airways bronchoconstriction than maximal expiratory flow-volume curves begun at total lung capacity. 2. In eight healthy men both maximal and partial expiratory flow-volume curves were measured where breath was held at total lun...

متن کامل

Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis.

New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We aimed to determine and optimize the technical performance and diagnostic accuracy of exhaled breath a...

متن کامل

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Anatomical dead space and airway resistance after glycopyrrolate or atropine premedication.

The effects of atropine and glycopyrrolate on anatomical dead space, one and three second forced expiratory volume, maximal expiratory flow rate, and total forced expiratory volume were determined in ten healthy volunteers. Using Fowler's single breath nitrogen analyzing technique, atropine was found to increase dead space by 19.2 per cent at one hour, declining to 11.02 per cent at four hours....

متن کامل

Standardised exhaled breath collection for the measurement of exhaled volatile organic compounds by proton transfer reaction mass spectrometry

BACKGROUND Exhaled breath volatile organic compound (VOC) analysis for airway disease monitoring is promising. However, contrary to nitric oxide the method for exhaled breath collection has not yet been standardized and the effects of expiratory flow and breath-hold have not been sufficiently studied. These manoeuvres may also reveal the origin of exhaled compounds. METHODS 15 healthy volunte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014