The electrochemical and fluorescence detection of nitric oxide in the cochlea and its increase following loud sound.
نویسندگان
چکیده
A nitric oxide (NO)-selective sensor (tip diameter 30 microm) was inserted into the perilymph of the basal turn of the guinea pig cochlea. The basal level and stimulation-induced changes of NO were measured. The mean (+/-S.E.M.) basal level of NO was 273+/-42.9 nM. Following perilymphatic perfusion of the artificial perilymph containing NO synthase (NOS) substrate L-arginine (100 microM) combined with cofactor (6R)-5,6,7,8-tetrahydrobiopterin dihydrochloride (100 microM), a rapid and significant increase of NO to a mean concentration of 392+/-32.3 nM (P < 0.01, n = 10) was recorded. In contrast, a significant decrease of mean NO concentration to 180+/-32.7 nM (P < 0.01, n = 10) was observed following the perfusion of the NOS-inhibiting agent N(G)-nitro-L-arginine methyl ester (100 microM). No change in the NO concentration was found following the perfusion of either artificial perilymph or N(G)-monomethyl-D-arginine (100 microM) solution employed as controls. Broadband noise exposure (3 h/day at 120 dBA SPL) for three consecutive days produced an increase in NO concentration to 618+/-60.7 nM (P < 0.05, n = 10) in the perilymph. In addition, by using specific dyes for NO, 4,5-diaminofluoresceine diacetate and for the reactive oxygen species (ROS), dihydrorhodamine 1,2,3, the distribution of NO in the whole mounts of the organ of Corti and the production of ROS in vivo in the organ of Corti were investigated in both control (n = 5) and noise-exposed (n = 5) animals. The more intense NO and ROS fluorescence was observed in both the inner and outer hair cells in the noise-exposed groups. It is proposed that both the basal level and the increase in NO concentration following the addition of substrate (L-arginine) are produced by the constitutive NOS while the elevated NO and ROS following noise exposure indicate that NO may be involved in noise-induced hearing loss.
منابع مشابه
Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملSynergistic Effect of LPS, IFN- and Iron on Apoptosis of Balb/c Mice Macrophages Following Nitric Oxide Production
Objective(s) Previous studies have demonstrated that the nitric oxide (NO) dependent death of murine peritoneal macrophages activated in vitro with IFN-g and LPS is mediated through apoptosis. In the present study, we investigated the synergistic effect of LPS, IFN-g and iron on NO production and apoptosis. Materials and Methods After determination of iron cytotoxicity, the peritoneal macrop...
متن کاملDeveloped Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملComparison of Nitric Oxide Changes in Hippocampal Tissue and Pain Sensation in Male Rats Parkinson's Model Following 6 Weeks of Continuous and Intermittent Training
Introduction: Despite the beneficial roles of nitric oxide, its excessive synthesis causes neurodegenerative diseases. Therefore, the aim of the present study was to compare the nitric oxide changes in the hippocampal tissue and the pain sensation of male Parkinson's rats after 6 weeks of continuous and interval training. Methods: In this experimental study, 24 Wistar male rats were used. Rats...
متن کاملP-90: The Effect of Nitric Oxide on Mouse Oocyte in Vitro Maturation in Two and Three Dimensional Conditions
Background: In vitro culture of ovarian follicles may preserve fertility in women with premature ovarian failure due to cancer .It seems that creation a condition that could maintain cellular communications and supports growth of follicles to produce mature oocytes appear to be essential. Nitric oxide (NO) has been recently shown to act with a dual action in mouse oocyte meiotic maturation depe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hearing research
دوره 164 1-2 شماره
صفحات -
تاریخ انتشار 2002