The magic angle phenomenon in tendons: effect of varying the MR echo time.

نویسندگان

  • W C Peh
  • J H Chan
چکیده

Increased signal intensity on magnetic resonance (MR) imaging of tendons arising from the magic angle phenomenon is well recognized. This study aimed to evaluate the effect of varying the echo time (TE) upon tendon signal intensity, and to determine if a modified TE value produces acceptable T1 and proton density (PD) weighted images. Fresh bovine tendons were imaged in a 1.5 T MR scanner using spin echo (SE) T1 and PD weighted sequences and utilizing a number of different coils. For each set of sequences, the tendon was orientated at 55 degrees to the main magnetic field (B0) and imaged using constant TR and incremental TE values. Signal intensity was measured on images at each TR/TE value and compared with the signal intensities of tendons orientated at 0 degree to B0, obtained using minimum TE values. This experiment was repeated with a 1.0 T MR scanner and utilizing a spine coil. The Achilles tendon of a human volunteer was similarly imaged using a general purpose flex coil. For bovine and human tendons orientated at 55 degrees to B0, the signal intensities decreased exponentially with increasing TE. A critical TE value exceeding 37 ms, for each sequence, reduced the signal intensities to the levels obtained with the tendons orientated at 0 degree to B0, such that the magic angle phenomenon could be avoided. Although there was variability of the signal intensities with different coils, the critical TE value remained constant and the anatomical clarity was not degraded. The critical TE value was unaltered using two MR scanners of different field strengths.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magic angle effect in normal collateral ligaments of the distal interphalangeal joint in horses imaged with a high-field magnetic resonance imaging system.

Distal forelimb specimens of eight skeletally mature horses were imaged using proton density turbo spin echo, T1-weighted spoiled gradient echo, T2*-weighted gradient echo, short tau inversion recovery and T2-weighted fast spin echo sequences with the limb parallel to the main magnetic field, and with angulation of the limb relative to the main magnetic field. The magic angle effect can be iden...

متن کامل

A MR Compatible Mechatronic System to Facilitate Magic Angle Experiments in Vivo

When imaging tendons and cartilage in a MRI scanner, an increase in signal intensity is observed when they are oriented at 55 degrees with respect to Bo (the "magic angle"). There is a clear clinical importance for considering this effect as part of the diagnosis of orthopaedic and other injury. Experimental studies of this phenomenon have been made harder by practical difficulties of tissue po...

متن کامل

The magic angle effect: a source of artifact, determinant of image contrast, and technique for imaging.

This review provides a formalism for understanding magic angle effects in clinical studies. It involves consideration of the fiber-to-field angle for linear structures such as tendons, ligaments, and peripheral nerves, disc-like and circular structures such as menisci and labra, as well as complex three-dimensional structures. There may be one or more fiber types with different orientations wit...

متن کامل

Magnetic resonance histologic correlation in rotator cuff tendons.

PURPOSE To relate histologic changes in rotator cuff tendons to the appearance on T1-weighted as well as fat-suppressed T2-weighted and proton density-weighted magnetic resonance imaging (MRI) sequences. MATERIALS AND METHODS T1-weighted, fat-suppressed T2-weighted and fat-suppressed proton density-weighted sequences of 18 cadaveric shoulders were acquired. The supraspinatus, infraspinatus, a...

متن کامل

Magic angle effects in MR neurography.

BACKGROUND AND PURPOSE Magic angle effects are well recognized in MR imaging of tendons and ligaments, but have received virtually no attention in MR neurography. We investigated the hypothesis that signal intensity from peripheral nerves is increased when the nerve's orientation to the constant magnetic induction field (B(0)) approaches 55 degrees (the magic angle). METHODS Ten volunteers we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 71 841  شماره 

صفحات  -

تاریخ انتشار 1998