Calculating the peak skin dose resulting from fluoroscopically guided interventions. Part I: Methods

نویسندگان

  • A. Kyle Jones
  • Alexander S. Pasciak
چکیده

While direct measurement of the peak skin dose resulting from a fluoroscopically-guided procedure is possible, the decision must be made a priori at additional cost and time. It is most often the case that the need for accurate knowledge of the peak skin dose is realized only after a procedure has been completed, or after a suspected reaction has been discovered. Part I of this review article discusses methods for calculating the peak skin dose across a range of clinical scenarios. In some cases, a wealth of data are available, while in other cases few data are available and additional data must be measured in order to estimate the peak skin dose. Data may be gathered from a dose report, the DICOM headers of images, or from staff and physician interviews. After data are gathered, specific steps must be followed to convert dose metrics, such as the reference point air kerma (K(a,r)) or the kerma area product (KAP), into peak skin dose. These steps require knowledge of other related factors, such as the f-factor and the backscatter factor, tables of which are provided in this manuscript. Sources of error and the impact of these errors on the accuracy of the final estimate of the peak skin dose are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculating the peak skin dose resulting from fluoroscopically‐guided interventions. Part II: Case studies†

Part II of this review article presents four case studies for which peak skin doses are calculated following the methods outlined in Part I of this review. The data available in the cases ranges from proprietary dose reports to fluoroscopy time and number of digital acquisition frames only. Flowcharts are provided for each case. These flowcharts outline the calculation steps and data sources us...

متن کامل

Minimizing radiation-induced skin injury in interventional radiology procedures.

Skin injury is a deterministic effect of radiation. Once a threshold dose has been exceeded, the severity of the radiation effect at any point on the skin increases with increasing dose. Peak skin dose is defined as the highest dose delivered to any portion of the patient's skin. Reducing peak skin dose can reduce the likelihood and type of skin injury. Unfortunately, peak skin dose is difficul...

متن کامل

Radiation injury is a potentially serious complication to fluoroscopically-guided complex interventions

Radiation-induced injury to skin is an infrequent but potentially serious complication to complex fluoroscopically-guided interventional procedures. Due to a lack of experience with such injuries, the medical community has found fluoroscopically-induced injuries difficult to diagnose. Injuries have occurred globally in many countries. Serious injuries most frequently occur on the back but have ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011