Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

نویسندگان

  • J A Tanyi
  • C M Kato
  • Y Chen
  • Z Chen
  • M Fuss
چکیده

OBJECTIVES The impact of two multileaf collimator (MLC) systems for linear accelerator-based intracranial stereotactic radiosurgery (SRS) was assessed. METHODS 68 lesions formed the basis of this study. 2.5 mm leaf width plans served as reference. Comparative plans, with identical planning parameters, were based on a 5 mm leaf width MLC system. Two collimation strategies, with collimation fixed at 0° or 90° and optimised per arc or beam, were also assessed. Dose computation was based on the pencil beam algorithm with allowance for tissue heterogeneity. Plan normalisation was such that 100% of the prescription dose covered 95% of the planning target volume. Plan evaluation was based on target coverage and normal tissue avoidance criteria. RESULTS The median conformity index difference between the MLC systems ranged between 0.8% and 14.2%; the 2.5 mm MLC exhibited better dose conformation. The median reduction of normal tissue exposed to ≥100%, ≥50% and ≥25% of the prescription dose ranged from 13.4% to 29.7%, favouring the 2.5 mm MLC system. Dose fall-off was steeper for the 2.5 mm MLC system with an overall median absolute difference ranging from 0.4 to 1.2 mm. The use of collimation optimisation resulted in a decrease in differences between the MLC systems. The results demonstrated the dosimetric merit of the 2.5 mm leaf width MLC system over the 5 mm leaf width system, albeit small, for the investigated range of intracranial SRS targets. CONCLUSION The clinical significance of these results warrants further investigation to determine whether the observed dosimetric advantages translate into outcome improvements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film

Micro-multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation sys...

متن کامل

Quantifying isocenter measurements to establish clinically meaningful thresholds

A dataset range of isocenter congruency verification tests have been examined from a statistical perspective for the purpose of establishing tolerance levels that are meaningful, based on the fundamental limitation of linear accelerator isocentricity and the demands of a high-precision stereotactic radiosurgery program. Using a laser-defined isocenter, a total of 149 individual isocenter congru...

متن کامل

Dosimetric performance of the new high‐definition multileaf collimator for intracranial stereotactic radiosurgery

The objective was to evaluate the performance of a high-definition multileaf collimator (MLC) of 2.5 mm leaf width (MLC2.5) and compare to standard 5 mm leaf width MLC (MLC5) for the treatment of intracranial lesions using dynamic conformal arcs (DCA) technique with a dedicated radiosurgery linear accelerator. Simulated cases of spherical targets were created to study solely the effect of targe...

متن کامل

SU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy.

PURPOSE To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. METHODS We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here ...

متن کامل

The photon beam characteristics of linear accelerator equipped with additional narrow beam collimator

Stereotactic radiosurgery (SRS) using external beams of radiation has become an important method of treatment of small intracranial lesions such as arteriovenous malformations, benign or malignant primary tumours and isolated metastases. In this technique, a high dose of radiation is delivered to the stereotactically localized lesion, the adjacent normal brain tissue being minimaly irradiated.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 84 1003  شماره 

صفحات  -

تاریخ انتشار 2011