Model-based navigation of left and right ventricular leads to optimal targets for cardiac resynchronization therapy: a single-center feasibility study.

نویسندگان

  • Zachary Laksman
  • Raymond Yee
  • John Stirrat
  • Lorne J Gula
  • Allan C Skanes
  • Peter Leong-Sit
  • Jamie Manlucu
  • David McCarty
  • Yosra Turkistani
  • David Scholl
  • Martin Rajchl
  • Aashish Goela
  • Ali Islam
  • R Terry Thompson
  • Maria Drangova
  • James A White
چکیده

BACKGROUND Left ventricular (LV) and right ventricular pacing site characteristics have been shown to influence response to cardiac resynchronization therapy (CRT). This study aimed to determine the clinical feasibility of image-guided lead delivery using a 3-dimensional navigational model displaying both LV and right ventricular (RV) pacing targets. Serial echocardiographic measures of clinical response and procedural metrics were evaluated. METHODS AND RESULTS Thirty-one consecutive patients underwent preimplant cardiac MRI with the generation of a 3-dimensional navigational model depicting optimal segmental targets for LV and RV leads. Lead delivery was guided by the model in matched views to intraprocedural fluoroscopy. Blinded assessment of final lead tip location was performed from postprocedural cardiac computed tomography. Clinical and LV remodeling response criteria were assessed at baseline, 3 months, and 6 months using a 6-minute hall walk, quality of life questionnaire, and echocardiography. Mean age and LV ejection fraction was 66 ± 8 years and 26 ± 8%, respectively. LV leads were successfully delivered to a target or adjacent segment in 30 of 31 patients (97%), 68% being nonposterolateral. RV leads were delivered to a target or adjacent segment in 30 of 31 patients (97%), 26% being nonapical. Twenty-three patients (74%) met standard criteria for response (LV end-systolic volume reduction ≥ 15%), 18 patients (58%) for super-response (LV end-systolic volume reduction ≥ 30%). LV ejection fraction improved at 6 months (31 ± 8 versus 26 ± 8%, P=0.04). CONCLUSIONS This study demonstrates clinical feasibility of dual cardiac resynchronization therapy lead delivery to optimal targets using a 3-dimensional navigational model. High procedural success, acceptable procedural times, and a low rate of early procedural complications were observed. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01640769.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical feasibility of targeted cardiac resynchronization lead delivery using a 3D MRI cardiac model

Background Cardiac resynchronization therapy (CRT) aims to reduce dyssynchronous contraction through simultaneous pacing of the right ventricular (RV) septum and left ventricular (LV) lateral wall. Up to 40% of patients do not respond, largely attributed to lack of dysynchrony and/ or transmural scar at pacing sites. In this pilot study we tested the feasibility of guiding LV and RV leads to “o...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Myocardial infarction does not preclude electrical and hemodynamic benefits of cardiac resynchronization therapy in dyssynchronous canine hearts.

BACKGROUND Several studies suggest that patients with ischemic cardiomyopathy benefit less from cardiac resynchronization therapy. In a novel animal model of dyssynchronous ischemic cardiomyopathy, we investigated the extent to which the presence of infarction influences the short-term efficacy of cardiac resynchronization therapy. METHODS AND RESULTS Experiments were performed in canine hear...

متن کامل

Acute and mid-term outcomes of transvenous implant of a new left ventricular quadripolar lead versus bipolar leads for cardiac resynchronization therapy: results from a single-center prospective database.

BACKGROUND The purpose of this study was to evaluate the feasibility of the use of a quadripolar left ventricular (LV) lead for cardiac resynchronization therapy and to compare its acute and mid-term outcomes with those obtained with bipolar leads. Cardiac resynchronization exhibits a high incidence of problems involving the LV lead when conventional leads are used, and these problems may be mi...

متن کامل

Simultaneous His Bundle and Left Ventricular Pacing for Optimal Cardiac Resynchronization Therapy Delivery: Acute Hemodynamic Assessment by Pressure-Volume Loops.

BACKGROUND Previous studies have investigated the role of intrinsic conduction in optimizing cardiac resynchronization therapy. We investigated the role of fusing pacing-induced activation and intrinsic conduction in cardiac resynchronization therapy by evaluating the acute hemodynamic effects of simultaneous His-bundle (HIS) and left ventricular (LV) pacing. METHODS AND RESULTS We studied 11...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2014