Comparison of vena contracta width by multiplane transesophageal echocardiography with quantitative Doppler assessment of mitral regurgitation.

نویسندگان

  • S K Heinle
  • S A Hall
  • M E Brickner
  • D L Willett
  • P A Grayburn
چکیده

Mitral regurgitation (MR) severity is routinely assessed by Doppler color flow mapping, which is subject to technical and hemodynamic variables. Vena contracta width may be less influenced by hemodynamic variables and has previously been shown to correlate with angiographic estimates of MR severity. This study was performed to compare mitral vena contracta width by multiplane transesophageal echocardiography (TEE) with simultaneous quantitative Doppler echocardiography in 35 patients with MR. The vena contracta width was measured at the narrowest portion of the MR jet as it emerged through the coaptation of the leaflets; it was identified in 97% of the patients. Vena contracta width correlated well with regurgitant volume (R2 = 0.81) and regurgitant orifice area (R2 = 0.81) by quantitative Doppler technique. A vena contracta width > or = 0.5 cm always predicted a regurgitant volume >60 ml and an effective regurgitant orifice area > or = 0.4 cm2 in all patients. A vena contracta width < or = 0.3 cm always predicted a regurgitant volume <45 ml and a regurgitant orifice area < or = 0.35 cm2. Thus, vena contracta width by multiplane TEE correlates well with mitral regurgitant volume and regurgitant orifice area by quantitative Doppler echocardiography and provides a simple method for the identification of patients with severe MR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Mathematical Evaluation of Mitral Regurgitation Severity with EROA

It is to be investigated and verified that vena contracta width (VCW) obtained from color Doppler images and effective regurgitant orifice area (EROA) obtained from the VCW is capable of quantifying the severity of mitral regurgitation (MR). A mathematical expression has been developed between VCW and EROA. Vena contracta width is an efficient method for grading the severity of MR, but it is ve...

متن کامل

Assessment of Mitral Regurgitation Severity by Doppler Color Flow Mapping of the Vena Contracta in Dogs

BACKGROUND Although Doppler color flow mapping is widely used to assess the severity of mitral regurgitation (MR), a simple, accurate, and quantitative marker of MR by color flow mapping remains elusive. We hypothesized that vena contracta width by color flow mapping would accurately predict the severity of MR. METHODS AND RESULTS We studied 80 patients with MR. Vena contracta width was measu...

متن کامل

Assessment of aortic regurgitation by transesophageal color Doppler imaging of the vena contracta: validation against an intraoperative aortic flow probe.

OBJECTIVES This study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV). BACKGROUND Color Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity ...

متن کامل

Assessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: usefulness and validation.

In this report, we evaluate 56 consecutive adult patients who underwent standard two-dimensional (2D) and live three-dimensional transthoracic echocardiography (3D TTE), as well as left heart catheterization with aortography (45 patients) or cardiac surgery (11 patients), for evaluation of aortic insufficiency. Similar to the method we previously described for mitral insufficiency, aortic regur...

متن کامل

Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography.

BACKGROUND Analysis of procedural effects in patients undergoing percutaneous mitral valve repair (PMVR) using the edge-to-edge technique is complex, and common methods to define mitral regurgitation severity based on 2-dimensional (2D) echocardiography are not validated for postprocedural double-orifice mitral valve. This study used 3D transesophageal echocardiography (TEE) to determine the fu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of cardiology

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 1998