Towards Beam Hardening Correction for Polychromatic X-ray Ct
نویسندگان
چکیده
High-attenuation object-induced streaking and shadow artifacts in computerized tomography (CT) are somewhat connected to the misfit of the X-ray projection data to the range space of the Radon transform. This misfit is mainly due to the beam hardening factor of the projection data which is unavoidable for polychromatic sources. The major difficulty in dealing with the beam hardening-induced streaking and shadow artifacts comes from its highly nonlinear nature depending on geometries of high attenuation objects. In this work, we investigate the mathematical characteristics of those streaking and shadow artifacts from the structure of the projection data. We also proposed a metal artifacts reduction method by incorporating the recent technique of the nonlinear beam-hardening corrector. Numerical simulations show that the proposed method effectively alleviates the streaking artifacts without changing the background images. Mathematics subject classification: 65N38, 65N30.
منابع مشابه
Beam Hardening Correction with an Iterative Scheme Using an Exact Backward Projector and a Polychromatic Forward Projector
In computed tomography (CT), reconstructions from conebeam (CB) data acquired with a polychromatic X-ray device show so called beam hardening artifacts. Beam hardening artifacts are highly undesirable for a medical diagnosis, because details in the reconstructed image are severely disturbed or completely lost. In this work, we demonstrate the significant reduction of beam hardening artifacts by...
متن کاملThe application of X-ray beam hardening correction based on polynomial fitting in local scan
2 national X ray digital imaging center; Mianyang,China Abstract Beam Hardening effect would be induced due to broad energy spectrum of X-ray. Beam Hardening would lead to artifacts in CT reconstructed images, such as cupping artifact, streak artifact and metal artifact, so that the quality of CT image degrades. One efficient beam hardening correction method is building a mathematical law betwe...
متن کاملMulti-Material Beam Hardening Correction(MMBHC) in Computed Tomography
In computed tomography (CT), the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. State-of-theart methods to correct the beam hardening effect are mostly single material precorrections (e.g. water-precorrection), which are far less efficient when more than one material is present in the field of measurement. The use of tho...
متن کاملAn iterative approach to the beam hardening correction in cone beam CT.
In computed tomography (CT), the beam hardening effect has been known to be one of the major sources of deterministic error that leads to inaccuracy and artifact in the reconstructed images. Because of the polychromatic nature of the x-ray source used in CT and the energy-dependent attenuation of most materials, Beer's law no longer holds. As a result, errors are present in the acquired line in...
متن کاملReferenceless Beam Hardening Correction in 3D Computed Tomography Images of Multi-Material Objects
We propose a new method to reduce the effects of non-linearities such as beam hardening in Computed Tomography (CT) images. Due to the polychromatic characteristics of X-ray sources the ratio of attenuated and incoming intensity is not exactly exponential with the material thickness. Within CT images this leads to artifacts like cupping, streaks and blurring. Especially in multi-material object...
متن کامل