Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: a bench study.

نویسندگان

  • Yusuke Chikata
  • Jun Oto
  • Mutsuo Onodera
  • Masaji Nishimura
چکیده

BACKGROUND Heat and moisture exchangers (HMEs) are commonly used for humidifying respiratory gases administered to mechanically ventilated patients. While they are also applied to tracheostomized patients with spontaneous breathing, their performance in this role has not yet been clarified. We carried out a bench study to investigate the effects of spontaneous breathing parameters and oxygen flow on the humidification performance of 11 HMEs. METHODS We evaluated the humidification provided by 11 HMEs for tracheostomized patients, and also by a system delivering high-flow CPAP, and an oxygen mask with nebulizer heater. Spontaneous breathing was simulated with a mechanical ventilator, lung model, and servo-controlled heated humidifier at tidal volumes of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. Expired gas was warmed to 37°C. The high-flow CPAP system was set to deliver 15, 30, and 45 L/min. With the 8 HMEs that were equipped with ports to deliver oxygen, and with the high-flow CPAP system, measurements were taken when delivering 0 and 3 L/min of dry oxygen. After stabilization we measured the absolute humidity (AH) of inspired gas with a hygrometer. RESULTS AH differed among HMEs applied to tracheostomized patients with spontaneous breathing. For all the HMEs, as tidal volume increased, AH decreased. At 20 breaths/min, AH was higher than at 10 breaths/min. For all the HMEs, when oxygen was delivered, AH decreased to below 30 mg/L. With an oxygen mask and high-flow CPAP, at all settings, AH exceeded 30 mg/L. CONCLUSIONS None of the HMEs provided adequate humidification when supplemental oxygen was added. In the ICU, caution is required when applying HME to tracheostomized patients with spontaneous breathing, especially when supplemental oxygen is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of humidification performance: still no easy method!

All authors agree that humidification of gas delivered to patients during mechanical ventilation is essential.1 The upper airways normally provide 75% of the heat and moisture supplied to the alveoli.2 When bypassed, humidification of the gas is necessary to prevent hypothermia, inflammation of the airway epithelium, bronchospasm, atelectasis, and airway obstruction.1 There is, however, still a...

متن کامل

Heated air humidification versus cold air nebulization in newly tracheostomized patients

BACKGROUND After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). METHODS Newly tracheostomized...

متن کامل

Humidification performance of two high-flow nasal cannula devices: a bench study.

INTRODUCTION Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. METHODS We evaluated 2 HFNC (Airvo 2 and Opt...

متن کامل

Spontaneous Breathing Trial a Reliable Method for Weaning in Children

Introduction  Mechanical ventilation may be lifesaving intervention,It can be associated with complications,Thus,successful weaning is constitutive.One of the factors which is  important in successful weaning is  method of weaning. It is shown that  weaning is conducted successfully by using Spontaneous Breathing Trial (SBT) through T-piece and pressure support (PS) ventilation.But few studies ...

متن کامل

Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.

OBJECTIVE During invasive mechanical ventilation, inspired gases must be humidified. We previously showed that high ambient temperature greatly impaired the hygrometric performance of heated wire-heated humidifiers. The aim of this bench and clinical study was to assess the humidification performance of passive and active heat and moisture exchangers (HMEs) and the impact of ambient temperature...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 9  شماره 

صفحات  -

تاریخ انتشار 2013