Complex intermittency in Switching converters
نویسندگان
چکیده
Intermittent instability is commonly observed in switching power supplies during the design and development phase. It manifests as symmetrical period-doubling bifurcation in the time domain with long intermittent periods. Such intermittent operation is considered undesirable in practice and is usually avoided by appropriate adjustments of circuit parameters. This paper explores the mechanism and conditions for the emergence of intermittency in a common voltage-mode controlled buck converter. It is found that interference at frequencies near the switching frequency or its rational multiples will induce intermittent operation. The strengths and frequencies of the interfering signals determine the type and period of intermittency. The problem is analyzed by transforming the conventional parameter-bifurcation analysis to a time-bifurcation analysis. Analytical results are verified by simulations and experimental measurements.
منابع مشابه
Intermittent Chaos in Switching Power Supplies Due to Unintended Coupling of Spurious Signals
This paper studies the “intermittent” chaos and subharmonics observed in switching dc/dc converters using a simple circuit model that describes possible unintended coupling of some weak spurious signal to the converter. The study shows that the signal strength and frequency of the intruding signal are vital parameters that affect the type of intermittent behavior and the period of intermittency...
متن کاملInvestigation of Novel Transformerless Converters for DC Microgrid: Design and Analysis
This paper proposes two new soft-switching transformerless converters with high voltage conversion ratio. These proposed converters achieve soft-switching each with a single auxiliary resonant cell. The merit of these converters is reduced switching losses with lesser number of devices. The main switching devices are turned off with zero current switching (ZCS). Apart from the soft-switching fe...
متن کامل"Intermittent" chaos and subharmonics in switching power supplies
This paper studies the “intermittent” chaos and subharmonics observed in switching dc/dc converters using a simple circuit model that describes possible unintended coupling of some weak spurious signal to the converter. The study shows that the signal strength and frequency of the intruding signal are vital parameters that affect the type of intermittent behaviour and the period of intermittenc...
متن کاملAnalysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کاملAnalysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- I. J. Bifurcation and Chaos
دوره 18 شماره
صفحات -
تاریخ انتشار 2008