چکیده
Purpose To compare biometric parameters between primary angle closure with longer axial length (AL) and those with medium or shorter AL. Methods We prospectively recruited 138 primary angle-closure patients. Low-coherence interferometry and ultrasound biomicroscopy examinations were performed before laser peripheral iridotomy and pilocarpine treatment. AL was categorized as shorter (<22.5 mm), medium (≥22.5 to <23.5 mm), or longer (≥23.5 mm). Anterior chamber depth and width (ACD and ACW), lens vault (LV), anterior vault (AV), relative AV (AV/AL), relative lens position (RLP, [ACD + 1/2 lens thickness]/AL), trabecular-ciliary angle (TCA), keratometry, and other biometric parameters were compared among different AL groups. Results Among 138 angle-closure patients, 15 (10.9%) patients had longer ALs, of which 11 (73.3%) were male. These angle-closure eyes with longer AL had flatter cornea (P = 0.006 and 0.022 for flat and steep keratometry) and larger ACW (P = 0.006), but smaller RLP (P = 0.019) than those with medium AL; similarly, they had flatter cornea (P < 0.001 for both flat and steep keratometry), and larger ACW (P < 0.001), AV (P = 0.004), and TCA (P = 0.024), but smaller relative AV (P = 0.040) and RLP (P = 0.005) than those with shorter AL. No significant differences were found in the other parameters. Conclusions Primary angle closure with longer AL was uncommon. Causes of angle closure in these atypical patients were manifold. These patients were predominantly male; they had smaller relative dimension of the anterior segment, flatter cornea, and more anterior RLP and less anteriorly rotated ciliary body compared with those angle-closure patients with relatively shorter AL.
منابع مشابه
The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure
Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...
متن کاملAssociation between axial length of the eye and primary angle closure glaucoma.
BACKGROUND Angle closure glaucoma is emerging as a leading cause of blindness in Asia. OBJECTIVE To compare the ocular axial length of normal individuals and the subjects with primary angle closure glaucoma. This study has been conducted to determine axial length of eye as a risk factor of primary angle closure glaucoma. MATERIALS AND METHODS A cross-sectional comparative study was carried ...
متن کاملOcular Biometry in Angle Closure
PURPOSE To compare ocular biometric parameters in primary angle closure suspects (PACS), primary angle closure glaucoma (PACG) and acute primary angle closure (APAC). METHODS This cross-sectional study was performed on 113 patients including 33 cases of PACS, 45 patients with PACG and 35 subjects with APAC. Central corneal thickness (CCT), axial length (AL), anterior chamber depth (ACD) and l...
متن کاملCentral corneal thickness. Ocular correlations in normal eyes and those with primary angle-closure glaucoma.
In recent papers (Lowe, I968, I969a) it was shown that in normal eyes, lens position and thickness were coordinated with axial length and radius of corneal curvature, whereas in eyes with primary angle-closure glaucoma these correlations were lacking. Throughout adult life, lenses increase in thickness at the same rate in normal eyes and those with angle-closure glaucoma, but no change could be...
متن کاملOcular biometry in the subtypes of primary angle closure glaucoma in University Malaya Medical Centre.
Thirty-seven consecutive patients (41 eyes) diagnosed with primary angle closure glaucoma (PACG) attending the Glaucoma Clinic in University Malaya Medical Centre, over a period of 6 months were categorized into acute, subacute and chronic PACG from their clinical presentation. Each case was subjected to automated refraction, A-scan biometry for anterior chamber depth, axial length and lens thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 59 3 شماره
صفحات -
تاریخ انتشار 2018