The current study reports comparing the postoperative mechanical properties of the anterior capsule between femtosecond laser capsulotomy (FLC) and continuous curvilinear capsulorhexis (CCC) of variable size and shape in porcine eyes. All CCCs were created using capsule forceps. Irregular or eccentric CCCs were also created to simulate real cataract surgery. For FLC, capsulotomies 5.3 mm in diameter were created using the LenSx® (Alcon) platform. Fresh porcine eyes were used in all experiments. The edges of the capsule openings were pulled at a constant speed using two L-shaped jigs. Stretch force and distance were recorded over time, and the maximum values in this regard were defined as those that were recorded when the capsule broke. There was no difference in maximum stretch force between CCC and FLC. There were no differences in circularity between FLC and same-sized CCC. However, same-sized CCC did show significantly higher maximum stretch forces than FLC. Teardrop-shaped CCC showed lower maximum stretch forces than same-sized CCC and FLC. Heart-shaped CCC showed lower maximum stretch forces than same-sized CCC. Conclusively, while capsule edge strength after CCC varied depending on size or irregularities, FLC had the advantage of stable maximum stretch forces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Manual, Femtosecond Laser, and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver Eyes.

PURPOSE To compare the anterior lens capsulotomy edge tear strength created by manual continuous curvilinear capsulorhexis (CCC), femtosecond laser capsulotomy (FSLC), and a new automated precision pulse capsulotomy (PPC) device. DESIGN A 3-arm study in paired human cadaver eyes. PARTICIPANTS A total of 44 eye specimens from 22 donors in the United States. METHODS Capsulotomy was performe...

متن کامل

Comparative evaluation of femtosecond laser-assisted cataract surgery and conventional phacoemulsification in white cataract

PURPOSE To compare femtosecond laser-assisted capsulotomy with conventional manual capsulorhexis in cases of white cataract. PATIENTS AND METHODS The prospective comparative study enrolled 80 eyes (80 patients) with white cataract that underwent either femtosecond laser-assisted cataract surgery (Group I, n=40) or conventional manual phacoemulsification (Group II, n=40) at a tertiary care oph...

متن کامل

Analysis of Femtosecond Laser Assisted Capsulotomy Cutting Edges and Manual Capsulorhexis Using Environmental Scanning Electron Microscopy

Purpose. To investigate the structure and irregularity of the capsulotomy cutting edges created by two femtosecond (FS) laser platforms in comparison with manual continuous circular capsulorhexis (CCC) using environmental scanning electron microscopy (eSEM). Methods. Ten anterior capsulotomies were obtained using two different FS laser cataract platforms (LenSx, n = 5, and Victus, n = 5). In ad...

متن کامل

The Advantages of Femtosecond Laser-assisted Cataract Surgery.

PURPOSE To present the advantages of performing femtosecond laser-assisted (Alcon-LenSx Inc.) cataract surgery. METHODS Cataract surgery was performed with the LenSx femtosecond laser (Alcon-LenSx Inc.) in 50 eyes of 50 patients. The laser was programmed to perform a 4,9-4,5 mm capsulorhexis, a 2,3 mm main corneal incision, two 1,3 mm side-port incisions and either a hybrid-pattern or a cylin...

متن کامل

Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies.

PURPOSE To evaluate a laser technique and manual technique to perform capsulorrhexis in cataract eyes. METHODS Anterior capsulotomy was performed with an intraocular femtosecond laser (LenSx Lasers Inc) in 54 eyes (FS group) and manual continuous curvilinear capsulorrhexis was performed in 57 eyes (CCC group). Circularity and area of capsulotomy and IOL decentration were measured using Photos...