Parallel Pencil-Beam Redefinition Algorithm

نویسندگان

  • Paul Alderson
  • Mark Wright
  • Amit Jain
  • Robert Boyd
چکیده

The growing sophistication in radiation treatment strategies requires the utilization of increasingly accurate, but computationally intense, dose algorithms, such as the electron pencil-beam redefinition algorithm (PBRA). The sequential implementation of the PBRA is in production use at the MD Anderson Cancer center. The PBRA is difficult to parallelize because of the large amounts of data involved that is accessed in an irregular pattern taking varying amounts of time in each iteration. A case study of the parallelization of the PBRA code on a Beowulf cluster using PVM and PThreads is presented. The solution uses a non-trivial way of exchanging minimal amount of data between processes to allow a natural partitioning to work. Multi-threading is used to cut down on the communication times between CPUs in the same box. Finally, an adaptive load-balancing technique is used to further improve the speedup.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Purpose: To evaluate the accuracy of electron dose calculated using the pencil-beam redefinition algorithm (PBRA) in patient-like 2D phantoms. With the recent availability of bolus electron conformal therapy (ECT), conforming of the 90% dose surface to the planning

ID: 16536 Title: Accuracy of electron dose from pencil-beam redefinition algorithm in patient-like 2D phantoms Purpose: To evaluate the accuracy of electron dose calculated using the pencil-beam redefinition algorithm (PBRA) in patient-like 2D phantoms. With the recent availability of bolus electron conformal therapy (ECT), conforming of the 90% dose surface to the planning target volume (PTV) ...

متن کامل

Comprehensive proton dose algorithm using pencil beam redefinition and recursive dynamic splitting

We describe a new pencil beam (PB) algorithm that computes, from first principles, absolute fluence or dose per incident proton charge in a known heterogeneous terrain irradiated by known proton beams. PB transport is by standard Fermi-Eyges theory. Heterogeneites are handled by breaking up PBs using redefinition and recursive dynamic splitting. The terrain is discretized into uniform or hetero...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

متن کامل

A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

Recent developments in radiation therapy have been focused on applications of charged particles, especially—protons. Proton therapy can allow higher dose conformality compared to conventional radiation therapy. Dose calculations have an integral role in the successful application of proton therapy. Over the years several dose calculation methods have been proposed in proton therapy. A common ch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003