Rigid inflatable gastrostomy tube malposition

نویسندگان

  • Timothy E. Murray
  • Michael J. Lee
چکیده

Rigid inflatable gastrostomy (RIG) tubes are widely used in contemporary clinical practice for a variety of indications. Insertion of RIG tubes is associated with a high technical success rate and low incidence of mortality. In this case report, a procedural pitfall associated with intraperitoneal-extragastric malposition is described. Rigorous assessment of abdominal radiographs, as well as awareness of the expected appearance of the RIG tube and gastropexy T-fasteners, allows the abdominal radiologist to detect early RIG position in the early postprocedural period. Abdominal radiography is a widely available and inexpensive technique. The high spatial resolution it provides makes it a valuable tool in determining hardware position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Malposition of a percutaneous endoscopic gastrostomy tube in the jejunum.

for replacement of a percutaneous endoscopic gastrostomy (PEG) tube. He had originally undergone PEG tube placement at our hospital 2 years ago, and after insertion the position of the hub had been checked by gastroscopy. However, placement of the most recent PEG tube had been done at another hospital 1 year ago, with no gastroscopic evaluation. When the patient attended our hospital 1 year lat...

متن کامل

Malposition of percutaneous endoscopic-guided gastrostomy: Guideline and management

Percutaneous endoscopic-guided gastrostomy (PEG) is done routinely on patients who suffer from inability to feed by mouth. PEG is generally considered a safe procedure with a low complication rate. A commonly underreported complication of PEG is malposition. This manuscript is a guideline to diagnosis and management of PEG malposition. We describe the different types of malposition, their diagn...

متن کامل

Stomal dilation of a rigid gastrostomy for endoscopic retrograde cholangiopancreatography (ERCP): novel technique using a standard duodenoscope.

angiopancreatography (ERCP) via a gastrostomy by stomal balloon dilation through a surgical or radiological gastrostomy site has been described in a few cases [1–3]. We report here a novel technique for dilating a rigid percutaneous endoscopic gastrostomy (PEG) stoma for therapeutic ERCP. A 69-year-old man with bile duct stones was hospitalized for acute cholangitis. A gastrostomy feeding tube ...

متن کامل

Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage

Managing a patient scheduled for bronchoesophageal fistula repair is challenging for the anesthetist. If appropriate ventilation strategy is not employed, serious complications such as hypoxemia, gastric distension, and pulmonary aspiration can occur. We present the case of a 62-year-old man with a bronchoesophageal fistula in the left main stem bronchus requiring the insertion of a Y-shaped tr...

متن کامل

Extubation Failure in an Adolescent Patient after General Anesthesia for Gastrostomy Tube Placement

Myasthenia gravis (MG) is an autoimmune disease resulting in destruction of the post-synaptic nicotinic receptors at the neuromuscular junction. Classically, the earliest symptoms of MG are ocular, including ptosis and diplopia. Other less common early symptoms include dysphagia and fatigable chewing. Our case report describes the unusual presentation of MG in a teenager patient and presented f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017