Reliability of multicenter pediatric echocardiographic measurements of left ventricular structure and function: the prospective P(2)C(2) HIV study.
نویسندگان
چکیده
BACKGROUND To assess the reliability of pediatric echocardiographic measurements, we compared local measurements with those made at a central facility. METHODS AND RESULTS The comparison was based on the first echocardiographic recording obtained on 735 children of HIV-infected mothers at 10 clinical sites focusing on measurements of left ventricular (LV) dimension, wall thicknesses, and fractional shortening. The recordings were measured locally and then remeasured at a central facility. The highest agreement expressed as an intraclass correlation coefficient (ICC=0.97) was noted for LV dimension, with much lower agreement for posterior wall thickness (ICC=0.65), fractional shortening (ICC=0.64), and septal wall thickness (ICC=0.50). The mean dimension was 0.03 cm smaller in central measurements (95% prediction interval [PI], -0.32 to 0.25 cm) for which 95% PI reflects the magnitude of differences between local and central measurements. Mean posterior wall thickness was 0.02 cm larger in central measurements (95% PI, -0.18 to 0.22 cm). Mean fractional shortening was 1% smaller in central measurements. However, the 95% PI was -10% to 8%, indicating that a fractional shortening of 32% measured centrally could be anywhere between 22% and 40% when measured locally. Central measurements of mean septal thickness were approximately 0.1 cm thicker than local ones (95% PI, -0.18 to 0.34 cm). Centrally measured wall thickness was more closely related to mortality and possibly was more valid than local measurements. CONCLUSIONS Although LV dimension was reliably measured, local measurements of LV wall thickness and fractional shortening differed from central measurements.
منابع مشابه
Reliability of Multicenter Pediatric Echocardiographic Measurements of Left Ventricular Structure and Function The Prospective PC HIV Study
Background—To assess the reliability of pediatric echocardiographic measurements, we compared local measurements with those made at a central facility. Methods and Results—The comparison was based on the first echocardiographic recording obtained on 735 children of HIV-infected mothers at 10 clinical sites focusing on measurements of left ventricular (LV) dimension, wall thicknesses, and fracti...
متن کاملComparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method
Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...
متن کاملEchocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation
Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...
متن کاملEvaluation of Cardiac Function in Patients with Thalassemia Intermedia
Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 104 3 شماره
صفحات -
تاریخ انتشار 2001