Optic Nerve Sheath Diameter Measurement During Diabetic Ketoacidosis: A Pilot Study

نویسندگان

  • Kelly R. Bergmann
  • Donna M. Milner
  • Constantinos Voulgaropoulos
  • Gretchen J. Cutler
  • Anupam B. Kharbanda
چکیده

Section Editor: Mark I. Langdorf, MD, MHPE Submission history: Submitted February 1, 2016; Revision received May 26, 2016; Accepted June 13, 2016 Electronically published July 25, 2016 Full text available through open access at http://escholarship.org/uc/uciem_westjem DOI: 10.5811/westjem.2016.6.29939 [West J Emerg Med. 2016;17(5)531-541.] Children’s Hospitals and Clinics of Minnesota, Department of Pediatric Emergency Medicine, Minneapolis, Minnesota Children’s Hospitals and Clinics of Minnesota, McNeely Pediatric Diabetes Center and Endocrinology Clinic, Minneapolis, Minnesota *

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Optic Nerve and Cerebral Edema in the Course of Diabetic Ketoacidosis

In the recent years we have been observing an increased incidence of type 1 diabetes in children and adolescents. This leads to a more frequent acute complication of type 1 diabetes among children with hyperglycemia. The most common of these is diabetic ketoacidosis (DKA), while cerebral edema is the most dangerous. In children with DKA, cerebral edema most often presents with clinical symptoms...

متن کامل

A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement

BACKGROUND Optic nerve sheath diameter (ONSD) measurement using ultrasound has been proposed as a rapid, non-invasive, point of care technique to estimate intra-cranial pressure (ICP). Ultrasonic measurement of the optic nerve sheath can be quite challenging and there is limited literature surrounding learning curves for this technique. We attempted to develop a method to estimate the reliabili...

متن کامل

Coronal Axis Measurement of the Optic Nerve Sheath Diameter.

OBJECTIVES The true optic nerve sheath diameter cutoff value for detecting elevated intracranial pressure is variable. The variability may stem from the technique used to acquire sonographic measurements of the optic nerve sheath diameter as well as sonographic artifacts inherent to the technique. The purpose of this study was to compare the traditional visual axis technique to an infraorbital ...

متن کامل

Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.

STUDY OBJECTIVE We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure. METHODS Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestandi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016