Comparison of the isolation of adducts of 2'-deoxycytidine and 2'-deoxyguanosine with phenylglycidyl ether by high-performance liquid chromatography on a reversed-phase column and a polystyrene-divinylbenzene column.
نویسندگان
چکیده
2'-Deoxycitidine (dCyd) and 2'-deoxyguanosine (dGuo) were subjected to reaction with phenylglycidyl ether (PGE) in methanol in order to study the formation of the corresponding 2'-deoxynucleoside adducts. Separation methods were developed on analytical and semi-preparative scales using high-performance liquid chromatography with photodiode-array detection on a reversed-phase column and on a polystyrene-divinylbenzene column. The use of the latter column was prompted by decomposition of the preparatively isolated dGuo-PGE adducts on the reversed-phase column. The use of a polystyrene-divinylbenzene column solved this problem and also revealed the presence of one more peak in both the dCyd- and dGuo-PGE reaction mixtures. The adducts of dCyd and dGuo were isolated on preparative reversed-phase and polystyrene-divinylbenzene columns and characterized by UV, fast atom bombardment mass and 360 MHz 1H NMR spectrometry. The adducts of dCyd were the diastereomers of N-3-(2-hydroxy-3-phenoxypropyl)-2'-deoxycytidine and N4-(2-hydroxy-3-phenoxypropyl)-2'-deoxycytidine whereas those of dGuo were the two diastereomers of N-7-(2-hydroxy-3-phenoxypropyl)-2'-deoxyguanosine and a third peak which appeared to be mainly N2-(2-hydroxy-3-phenoxypropyl)-2'-deoxyguanosine.
منابع مشابه
Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملHigh Performance Liquid Chromatography Determination of Sertraline in Human
An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with...
متن کاملSimulataneous Analysis of Trimethoprim and Sulphamethoxazole Drug Combinations in Dosage Forms by High Performance Liquid Chromatography
A sensitive high performance liquid chromathography (HPLC) analytical procedure was developed for the quantitive determination of trimethoprim (TM* and sulphamethoxazole (SM) in commercial dosage forms. C18 analytical column (stainless steel, 25 cm * 4.6 mm i.d.) was packed with 5-*m particles of the reversed phase material and used for assays. Mobile phase containing 0.025 M sodium phosphate...
متن کاملA simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography
دوره 541 1-2 شماره
صفحات -
تاریخ انتشار 1991