Power Quality Improvement for Grid Connected Wind Energy System Using Upfc
نویسندگان
چکیده
In this paper, a cascaded current–voltage control strategy is proposed for inverters to simultaneously improve the power quality of the inverter local load voltage and the current exchanged with the grid. It also enables seamless transfer of the operation mode from standalone to grid-connected or vice versa. The control scheme includes an inner voltage loop and an outer current loop, with both controllers designed using the fuzzy logic control and H∞ repetitive control strategy. This leads to a very low total harmonic distortion in both the inverter local load voltage and the current exchanged with the grid at the same time. The proposed control strategy can be used to single-phase inverters and three-phase four-wire inverters. It enables grid connected inverters to inject balanced clean currents to the grid even when the local loads (if any) are unbalanced and/or nonlinear. Simulation under different scenarios, with comparisons made to the current repetitive controller replaced with a current proportional–resonant controller, is presented to demonstrate the excellent performance of the proposed strategy.
منابع مشابه
Fault Tolerance and Power Quality Study of Dfig Based Wind Turbine System
Wind power is the fastest growing renewable source of electrical energy hence it has become necessary to address problems associated with maintaining a stable electric power system. The wind generated power is always fluctuating due to its time varying nature and causing stability problem. Unified Power Flow Controller (UPFC) is used to control the power flow in the transmission systems by cont...
متن کاملVoltage sag and Harmonics Mitigation in Grid Connected WECS using UPFC in ETAP
This paper demonstrates the mitigation of power quality issues in a grid connected wind energy conversion system using UPFC. The procedure to compensate the power quality issues like voltage sag and harmonics are presented. A Frame work for 25 bus test system is developed in the ETAP & load flow analysis &harmonic analysis is performed. It is observed that the UPFC is effective in compensating ...
متن کاملA DSTATCOM - Control Scheme for Power Quality Improvement of Grid Connected Wind Energy System for Balanced and Unbalanced Non linear Loads
One of the main problems in wind energy generation is the connection to the grid. Injection of wind power into the grid affects the power quality resulting in poor performance of the system. The wind energy system faces frequently fluctuating voltage due to the nature of wind and introduction of harmonics into the system. The influence of the wind turbine in the grid system concerning the power...
متن کاملPower Management in a Utility Connected Micro-Grid with Multiple Renewable Energy Sources
As an efficient alternative to fossil fuels, renewable energy sources have attained great attention due to their sustainable, cost-effective, and environmentally friendly characteristic. However, as a deficiency, renewable energy sources have low reliability because of their non-deterministic and stochastic generation pattern. The use of hybrid renewable generation systems along with the storag...
متن کاملStability Analysis, Control and Modeling of Micro-grid Connected to Wind Turbine: Effect of Optimal Amplified Converter
Wind turbines as a renewable energy are installed and operated as wind farms in various locations with windy climates. Connecting micro grids to wind turbines can lead to improved power generation and transmission to distribution networks. Therefore, formulating and configuring the micro-grid connected to the wind turbine requires accurate examination of the configuration of the micro-grid wit...
متن کامل