Precordial potentials wore synthesized from the components of the SVEC III vectorcardiographic system as an application of the Becking-Burger technic for testing the validity of the single dipole concept. The data was further utilized to construct Burger image loops from living subjects. Discrepancies from pure dipole theory and from the applicability of the SVEC III system are quantified. Limitations of even a perfect vectorcardiographic lead system are defined and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vectorcardiographic Studies in Acquired Valvular Disease with Reference to the Diagnosis of Right Ventricular Hypertrophy

or massive RVH can the electromotive forces generated in the right ventricle (RV) counterbalance those produced in the left ventricle (LV).1 2 Our experience as well as that of several others-9 has demonstrated the usefulness and merits of the orthogonal vectorcardiogram. Furthermore, Toshima et al.'0 using the Schmitt-Simonson system (SVEC III) in patients with mitral and aortic valvular disea...

متن کامل

Vectorcardiographic studies in acquired valvular disease with reference to the diagnosis of right ventricular hypertrophy.

or massive RVH can the electromotive forces generated in the right ventricle (RV) counterbalance those produced in the left ventricle (LV).1 2 Our experience as well as that of several others-9 has demonstrated the usefulness and merits of the orthogonal vectorcardiogram. Furthermore, Toshima et al.'0 using the Schmitt-Simonson system (SVEC III) in patients with mitral and aortic valvular disea...

متن کامل

Evaluation of precordial orthogonal vectorcardiographic lead ST-segment magnitude in the assessment of myocardial ischemic injury.

Relationship has been established between epicardial ST-segment elevation, considered a reliable estimate of ischemic injury in experimental myocardial damage, and ST changes by multiple-lead precordial electrocardiography. However, 35-lead precordial mapping is time-consuming and suitable only for anterior infarctions. An alternate, more rapid method for recording ST segments is an external 3-...

متن کامل

The effect of leads utilized upon discrepancies between spatial vectors recorded by SVEC and by mean vector methods.

IN a former study, 1 a statistical comparison was made between mean vectors, constructed from conventional ECG leads by means of a mechanical vector analyzer— method I—and the maximum instantaneous vectors as recorded with the SVEC' (stereovectorelectrocardiograph, method II). These two methods differ in regard to the leads used and the method of measurement of spatial vectors. The results were...

متن کامل

Intrinsic properties of uncorrected and highly corrected leads.

IT has become increasingly evident during the past several years that the single, fixedlocation dipole generator serves only as a firstorder approximation in accounting for the distribution of electrocardiographic potentials over the body surface.' 3 In principle any desired degree of approximation may be achieved by superimposing multipolar equivalent generators of higher order upon the dipole...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 1959