The PEG-PCL-PEG Hydrogel as an Implanted Ophthalmic Delivery System after Glaucoma Filtration Surgery; a Pilot Study

نویسندگان

  • Ribo Peng
  • Gang Qin
  • Xiabin Li
  • Hongbin Lv
  • Zhiyong Qian
  • Ling Yu
چکیده

Currently, filtration surgery has been considered as the most effective therapy for glaucoma; however, the scar formation in the surgical area may often lead to failure to the procedure. An implanted drug delivery system may provide localized and sustained release of a drug over an extended period. Poly (ethylene glycol)-poly (ε-caprolactone)-poly (ethylene glycol) (PEG-PCL-PEG, PECE) hydrogel has been successfully synthesized and determined as thermosensitive and biocompatible. In order to overcome the limitations of common local ophthalmic medications, we investigated the function of a self-assembled PECE hydrogel as an intracameral injection-implanted drug carrier to inhibit the formation of postoperative scarring. Following bevacizumal-loaded hydrogel intracameral injection into rabbit eyes, the status of the bleb and filtration fistula formed following the filtering surgery were examined through pathologic evaluation. Due to the sustained release of bevacizumab from the hydrogel, neovascularization and scar formation were inhibited; moreover, there were no corneal abnormalities and other ocular tissue damage found in the rabbits. This suggests that the PECE hydrogel may be considered as the novel biomaterial with potential as a sustained release system in glaucoma filtering surgery. Further studies require in shedding the light on the subject.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Characterization of PCL-PEG-PCL Copolymeric Nanoparticles as Polymersomes for Delivery Hydrophilic Drugs

Background: A novel drug delivery system using poly (ε-caprolactone) - poly (ethylene glycol) -poly (ε-caprolactone) (PCL-PEG-PCL) was established in this study. Methods: Ceftriaxone (CTX) was encapsulated within PCL-PEG-PCL nanoparticles by a double emulsion technique (w/o/w), leading to creation of ceftriaxone-loaded PCL-PEG-PCL (CTX/PCL-PEG-PCL) polymersomes. The resulting polymersomes...

متن کامل

Evaluation of an Injectable Thermosensitive Hydrogel As Drug Delivery Implant for Ocular Glaucoma Surgery

In this study, a biodegradable thermo-sensitive hydrogel from poly(trimethylene carbonate)15-F127-poly(trimethylene carbonate)15 (PTMC15-F127-PTMC15) was designed and evaluated as an injectable implant during ocular glaucoma filtration surgery in vivo and in vitro. Mitomycin C (MMC) was loaded into this hydrogel for controlled released to prolong the efficacy and to reduce the long-term toxicit...

متن کامل

Cisplatin-loaded superparamagnetic nanoparticles modified with PCL-PEG copolymers as a treatment of A549 lung cancer cells

Magnetic nanoparticles have been highly regarded because of their unique properties, such as hyperthermia, medicine control release, and diagnostic applications. The main aim of the current paper is to offer a new system for the modification of Fe3O4 (SPIONs) superparamagnetic nanoparticles physically and chemically with polymers through physical retention. These modified nanoparticles have bee...

متن کامل

Synthesis and characterization of mPEG-PCL copolymers as a polymersomes for delivery of enalapril as a model hydrophilic drug

Purpose: Enalapril maleate (EPM), was used for hypertension and congestive heart failure. In this way, an innovative delivery system with mPEG–PCL was synthesized and the release profile of the EPM from the drug-loaded polymersomes was evaluated. Methods: Di-block methoxy)-poly (ethylene glycol) - Poly (caprolactone) (mPEG-PCL) copolymers were synthesized and used to prepare of polymersom...

متن کامل

Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report

A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014