OBJECTIVE Numerous studies support the use of warmed intravenous fluids in hypothermic patients. The most effective method to accomplish this goal in a cold prehospital, wilderness, or combat setting is unknown. We evaluated various methods of warming intravenous fluids for a bolus infusion in a cold remote environment. METHODS One liter and 500 mL bags of intravenous fluid at 5 degrees C were heated using various methods in a 5 degrees C cold room. Methods included attachment of 3 types of chemical heat packs and heating the fluid in a pot on a camping stove. For all methods, fluids were run at a wide-open rate through an intravenous line with an 18-gauge catheter attached to the end to simulate a bolus infusion. The temperature of the fluid at the end of the intravenous line was measured. Each method was tested twice. Equipment weight and setup times are reported. Mean infusion temperatures for the various methods are compared. RESULTS Equipment weights ranged from 19 to 665 gm. Setup times ranged from 5 to 11 minutes. The 2 methods which achieved the desired mean infusion temperature of 35 to 42 degrees C without excessive maximum temperatures were 1) 2 Meal Ready to Eat hot packs attached to a 500 mL bag of fluid for 10 minutes prior to infusion, and 2) a camping stove heating the surface of a 500 mL bag of fluid to 75 degrees C prior to infusion. Other methods, including the use of commonly available heat packs and a commercially available IV fluid warmer were ineffective, with mean infusion temperatures ranging from 7 to 12 degrees C. CONCLUSIONS Heating of cold intravenous fluids in a cold environment is possible using either Meal Ready to Eat heat packs or a camping stove. Further study is needed to evaluate the ability of either method to consistently produce an appropriate fluid temperature given various ambient and initial fluid temperatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective evaluation of the contribution of ambient temperatures and transport times on infrared thermometry readings of intravenous fluids utilized in EMS patients

BACKGROUND During cold weather months in much of the country, the temperatures in which prehospital care is delivered creates the potential for inadvertently cool intravenous fluids to be administered to patients during their transport and care by emergency medical services (EMS). There is some potential for patient harm from unintentional infusion of cool intravenous fluids. Prehospital provid...

متن کامل

Mega Acer Kit® is more effective for warming the intravenous fluid than Ranger™ and ThermoSens® at 440 ml/h of infusion rate: an experimental performance study

BACKGROUND Few studies have investigated the effectiveness of intravenous fluid warmers at low and moderate flow rates below 1,000 ml/h. In this study, we compared the effectiveness of three different fluid warmers at a low flow rate (440 ml/h). METHODS We experimentally investigated the fluid warming performances of Mega Acer Kit® (Group M, n = 10), Ranger™ (Group R, n = 10), and ThermoSens®...

متن کامل

A comparative study on the effects of warm intravenous fluids, intravenous pethidine, and combined warm intravenous fluids and humid-warm oxygen on hemodynamic parameters after general anesthesia in patients with shivering in the recovery room

Introduction: Pethidine is commonly used to treat shivering after general anesthesia (GA), yet respiratory depression may subsequently occur. Warming methods such as warm fluids and/or humid-warm oxygen inhalation can reduce shivering after GA. This randomized clinical trial aimed to compare the effects of three different methods on the reduction of shivering and their hemodynamic and respirato...

متن کامل

The survey of Rrespiratory Rate, SPO2, nausea and vomiting in the use of three methods (warmed intravenous fluids, combined warming and pethidine) in patients with shivering

Introduction: Shivering after anaesthesia and surgery is a common complication. Different methods are used for control of shivering in the recovery room. The opioids such as pethidine are very common in shivering control. Pethidine can be induced apnea, respiratory depression and nausea &vomiting. The respiratory rate and spo2 can lead to more rapid diagnosis and treatment of serious hypoxemia ...

متن کامل

Quantification and assessment of effective of global warming on the occurrence of heat and cold waves in some selected stations in Iran

One of the atmospheric hazards that seriously affect human life and health is the occurrence of thermal tensions and stress in the form of heat and cold waves. Iran is one of the areas of the planet that has climate variability due to its geographical characteristics; therefore, consequently, its different regions are not immune to heat and cold waves. On the other hand, Iran's climate variabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Wilderness & environmental medicine

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2007