Oxygen Tension in the Aqueous Humor of Human Eyes under Different Oxygenation Conditions
نویسندگان
چکیده
PURPOSE To measure oxygen tension in the aqueous humor of human eyes under different oxygenation conditions. METHODS This prospective comparative interventional case series consisted of two parts. In the first part, 120 consecutive patients scheduled for cataract surgery were randomized into group I (control group) in which surgery was performed under local anesthesia inhaling 21% oxygen; group II in whom general anesthesia using 50% oxygen was employed; and group III receiving general anesthesia with 100% oxygen. After aspirating 0.2 ml aqueous humor under sterile conditions, the aqueous sample and a simultaneously drawn arterial blood sample were immediately analyzed using a blood gas analyzer. In part II the same procedures were performed in 10 patients after fitting a contact lens and patching the eye for 20 minutes (group IV) and in 10 patients after transcorneal delivery of oxygen at a flow rate of 5 L/min (group V). RESULTS Mean aqueous PO2 in groups I, II and III was 112.3±6.2, 141.1±20.4, and 170.1±27 mmHg, respectively (P values <0.001) and mean arterial PO2 was 85.7±7.9, 184.6±46, and379.1±75.9 mmHg, respectively (P values <0.001). Aqueous PO2 was 77.2±9.2 mmHg in group IV and 152.3±10.9 mmHg in group V (P values <0.001). There was a significant correlation between aqueous and blood PO2 (r=0.537, P<0.001). The contribution of atmospheric oxygen to aqueous PO2 was 23.7%. CONCLUSION Aqueous oxygen tension is mostly dependent on the systemic circulation and in part on the atmosphere. Increasing inspiratory oxygen and transcorneal oxygen delivery both increase aqueous PO2 levels.
منابع مشابه
The Effects of Glaucoma Drainage Devices on Oxygen Tension, Glycolytic Metabolites, and Metabolomics Profile of Aqueous Humor in the Rabbit
Purpose Glaucoma drainage device (GDD) implantation can lead to corneal decompensation. We evaluated changes over time in oxygen tension and in the metabolic environment of the aqueous humor after GDD implantation in the rabbit eye. Methods Ahmed Glaucoma Valves were implanted in the left eyes of eight male New Zealand white rabbits. Right eyes were used as a control. Oxygen tension was measu...
متن کاملThe aqueous humor is capable of generating and degrading H2O2.
PURPOSE To determine the ability of the aqueous humor to generate and degrade H2O2, the effect of environmental factors such as oxygen tension and temperature, and the constituents contributing to the observed results. METHODS Aqueous humor was carefully removed from bovine eyes within 3 hours of death. Standard and new techniques were used to follow H2O2 degradation and formation. Catalase a...
متن کاملIn vivo aqueous humor oxygen tension--as estimated from measurements on bare stroma.
Aqueous humor oxygen tension of the in vivo rabbit eye was estimated by a relatively atraumatic procedure. The anterior corneal surface of the eye was first scraped free of its epithelial layer. A polarographic oxygen electrode was then used to measure the oxygen tension at the bare stromal surface. Aqueous humor oxygen tension can be estimated from this measured steady-state stromal surface ox...
متن کاملIn vivo measurements of oxygen tension in the cornea, aqueous humor, and anterior lens of the open eye.
Measurements of oxygen profiles across the cornea, aqueous humor, and anterior lens differed from previously calculated values. The aqueous humor oxygen tension in paiticular also differed from previously measured values, being approximately 20 mm. Hg higher. Reasons for these differences are discussed. The tissue oxygen gradients measured confirm the high Qos of lenticular and corneal epitheli...
متن کاملOxygen tension in the anterior chamber of the rabbit eye.
The oxygen tension in the aqueous humor in the anterior chamber of rabbit eyes was measured continuously with a polarographic electrode. The normal oxygen tension in the anterior chamber was 23 +/- 2 mm Hg (mean +/- SD, n = 4). A contact lens was then placed on the cornea for at least 10 min and the drop in oxygen tension recorded. A hard polymethylmethacrylate lens reduced the oxygen tension b...