A Minimum Ten-year Review from an Independent Centre

نویسندگان

  • S. Hook
  • E. Moulder
  • P. J. Yates
  • B. J. Burston
  • E. Whitley
  • G. C. Bannister
چکیده

J Bone Joint Surg [Br] 2006;88-B:1584-90. Received 30 June 2006; Accepted after revision 15 August 2006 We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up. The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (1 stem), that for revision for any cause was 2.2% (2 stems), and for re-operation for any cause was 21.6% (19 hips). Re-operation was because of failure of the acetabular component in all but two hips. All but one femoral component subsided within the cement mantle to a mean of 1.52 mm (0 to 8.3) at the final follow-up. One further stem had subsided excessively (8 mm) and had lucent lines at the cement-stem and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. One stem was revised for deep infection and one for excessive peri-articular osteolysis. Defects of the cement mantle (Barrack grade C and D) were found in 28% of stems (25 hips), associated with increased subsidence (p = 0.01), but were not associated with endosteal lysis or failure. Peri-articular osteolysis was significantly related to the degree of polyethylene wear (p < 0.001), which was in turn associated with a younger age (p = 0.01) and male gender (p < 0.001). The use of the Exeter metal-backed acetabular component was a notable failure with 12 of 32 hips (37.5%) revised for loosening. The Harris-Galante components failed with excessive wear, osteolysis and dislocation with 15% revised (5 of 33 hips). Only one of 23 hips with a cemented Elite component (4%) was revised for loosening and osteolysis. Our findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracheal T-Tube Stent for Laryngotracheal Stenosis: Ten Year Experience

Introduction: The purpose of this retrospective study was to evaluate the outcome following stenting over a period of 10 years in patients with chronic laryngotracheal stenosis.   Materials and Methods: Between 2000–2010, out of 111 patients with laryngotracheal trauma, 71 underwent tracheal        T-stenting for laryngotracheal stenosis in the Department of Otorhinolaryngology at the Governmen...

متن کامل

Studying the ten-year performance of Geographical Researches quarterly journal

Aims & Backgrounds: The mission of scientific research journals is to publish scientific articles and help to disseminate information and the results of research about current developments in a scientific field. Today, the quantity and quality of scientific articles and journals published in a country is considered as one of the indicators of development and scientific credibility of that count...

متن کامل

Outcomes of Arthroscopic Biceps Tenodesis for the Treatment of Failed Type II SLAP Repair: A Minimum 2-Year Follow-Up

Background: To retrospectively review surgical outcomes of prospectively collected data on a series of patients whounderwent revision of a type II SLAP repair to arthroscopic biceps tenodesis due to an unsuccessful outcome.Methods: A retrospective review was performed on a cohort of patients who underwent arthroscopic biceps tenodesisfor a failed type II SLAP repair from 2010 ...

متن کامل

Retrospective Review of Trend in Modafinil Overexposures Reported to American Poison Information Centers

Background:Modafinil, a non-amphetamine central nervous system stimulant, is a wakefulness-promoting agent indicated for use in shift work sleep disorder, narcolepsy, and obstructive sleep apnea. The trend in modafinil overexposure over a ten-year period and the population likely to experience a resulting clinical effect is evaluated. Methods: Using data from the American Association of Poison ...

متن کامل

Does Mesenchymal Stem Cell Therapy Help Multiple Sclerosis Patients? Report of a Pilot Study

Background: Mesenchymal stem cells (MSCs) with their potential to differentiate into mesodermal and non-mesodermal lineages have several immunomodulatory characteris-tics. These properties make them promising tools in cell and gene therapy. Objective: To evaluate the potential therapeutic applications of autologous MSC in improving clinical manifestations of MS patients. Methods: Ten patients w...

متن کامل

Oligohydramnios and Pregnancy Outcome: Ten-Years Review

Oligohydramnios is frequently used to identify at risk fetuses. The purpose of this study was to assess adverse perinatal outcomes in oligohydramnios. Subjects comprised pregnant women diagnosed either with (590) or without (597) oligohydramnios who delivered after hospital admittance from 2000 to 2010 . Data, including the resuscitation of newborn, Apgar score at 5 min, NICU admission, death i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006