Shear Behavior of Single Cast-in Anchors in Plastic Hinge Zones
نویسندگان
چکیده
This paper presents two shear tests of -in. diameter cast-in anchors embedded in the plastic hinge zone of reinforced concrete columns. Design codes, such as ACI 318-14, require special reinforcement for concrete anchors in concrete that could be substantially damaged during an earthquake. The test anchors in this study were equipped with the anchor reinforcement recommended and verified in the literature. The column specimens were subjected to quasi-static cyclic loading before the test anchors were loaded in shear. Steel fracture was achieved in both test anchors despite cracks and concrete spalling occurred to the concrete within the plastic hinge zones. Meanwhile, the measured anchor capacities were smaller than the code-specified capacity, especially for the anchors subjected to cyclic shear. Concrete cover spalling was found critical to the observed capacity reduction, which caused combined bending and shear action in the anchor bolts. Measures should be developed to mitigate such adverse impact. In addition, further studies are needed for post-installed anchors before practical applications.
منابع مشابه
Flexural Behavior of Reinforced HPFRCC Beams
High Performance Fiber Reinforced Cementitious Composite (HPFRCC) materials exhibit strain hardening behavior with multiple cracking under tensile loading. In this paper, experimental and parametric studies are performed to assess the influence of using HPFRCC material instead of normal concrete in reinforced concrete beams. After calibrating the experimental results, the analytical results inc...
متن کاملCase Study on the Impact of Horizontal Boundary Elements Design on Seismic Behavior of Steel Plate Shear Walls
Acase studywas conducted to investigate the seismic behavior of steel plate shear walls having boundary elements designed by two different philosophies. The first design approach does not guarantee that formation of in-span plastic hinges on horizontal boundary elements (HBEs) will be prevented, whereas the second approach guarantees that plastic hinges can only occur at the ends of HBEs. Pusho...
متن کاملA COMPARATIVE STUDY OF OPTIMUM AND IRANIAN SEISMIC DESIGN FORCE DISTRIBUTIONS FOR STEEL MOMENT RESISTING BUILDINGS
In this study, constant-ductility optimization algorithm under a family of earthquake ground motions is utilized to achieve uniform damage distribution over the height of steel moment resisting frames (SMRFs). SMRF structures with stiffness-degrading hysteric behavior are modeled as single-bay generic frame in which the plastic hinge is confined only at the beam ends and the bottom of the first...
متن کاملEvaluation of Seismic Response of Concrete Structures Reinforced by Shape Memory Alloys (Technical Note)
Shape memory alloys (SMAs) are unique smart materials that have many advantages, such as ability to resist large strains without leaving residual strains and ability to recover original form. However, the high costs of SMAs have limited their usage. This paper evaluates the behavior of concrete structures equipped with SMAs in an optimal manner as they are being used along the plastic hinge of ...
متن کاملCombined Plastic Bending and Compression or Tension
So far we have assumed that a plastic hinge forms if the bending moment in a critical cross section reaches the plastic limit value, M0. We have tacitly neglected the effect of the other internal forces on the formation of the yield hinge. This effect, however, can be appreciable, for example in multi-storey frames or frames with a large horizontal thrust where the axial forces are large. So, w...
متن کامل