Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system
نویسندگان
چکیده
The 10 m prototype facility at the Albert–Einstein-institute (AEI) in Hanover, Germany, employs three large seismic attenuation systems to reduce mechanical motion. The AEI seismic-attenuation-system (AEI-SAS) uses mechanical anti-springs in order to achieve resonance frequencies below 0.5 Hz. This system provides passive isolation from ground motion by a factor of about 400 in the horizontal direction at 4 Hz and in the vertical direction at 9 Hz. The presented isolation performance is measured under vacuum conditions using a combination of commercial and custom-made inertial sensors. Detailed analysis of this performance led to the design and implementation of tuned dampers to mitigate the effect of the unavoidable higher order modes of the system. These dampers reduce RMS motion substantially in the frequency range between 10 and 100 Hz in 6 degrees of freedom. The results presented here demonstrate that the AEI-SAS provides substantial passive isolation at all the fundamental mirror-suspension resonances. G Bergmann et al Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system Printed in the UK 065002 CQGRDG © 2017 IOP Publishing Ltd 34 Class. Quantum Grav.
منابع مشابه
Performance Evaluation of Viscoelastic and Friction Passive Damping System in Steel Structures
Additional dampers are employed in order to decrease the dynamic response of structure against the earthquake and wind loading recently. In this study, two types of systems related to waste of inactive energy, i.e. frictional damper which is categorized in dampers dependent on movement and viscoelastic damper which is categorized in dampers dependent on velocity, in making steel structures resi...
متن کاملApplication of Single-Frequency Time-Space Filtering Technique for Seismic Ground Roll and Random Noise Attenuation
Time-frequency filtering is an acceptable technique for attenuating noise in 2-D (time-space) and 3-D (time-space-space) reflection seismic data. The common approach for this purpose is transforming each seismic signal from 1-D time domain to a 2-D time-frequency domain and then denoising the signal by a designed filter and finally transforming back the filtered signal to original time domain. ...
متن کاملApplication of Shape Memory Alloys in Seismic Isolation: A Review
In the last two decades, there has been an increasing interest in structural engineering control methods. Shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. Characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...
متن کاملAnalysis of Low-Frequency Passive Seismic Attributes in Maroun Oil Field, Iran
Nowadays, viable and cost-effective methods play a vital role in hydrocarbon exploration up to the point that geoscientists cannot rule out the importance of the passive seismic method (PSM) in oil exploration operations. This method is based on seismic energy, which has a natural source. This study focuses on seismic energy anomaly of 1-6 Hz. Some researches show that spectral and polarization...
متن کاملA Comparative Study on Seismic Performance of Hexagrid, Diagrid and Tubular Structural Systems
Hexagrid structural system is an innovated system with structural behavior which is similar to a tubular system. In this paper, a numerical study is conducted to estimate the seismic performance of horizontal hexagrid concerning the combined horizontal and vertical hexagrid, tubular and diagrid structural systems. First 30 and 50 story buildings are modeled using ETABS, then pushover and nonlin...
متن کامل