Artifact-free 3D Reconstruction for Optical Projection Tomography
نویسندگان
چکیده
Optical Projection Tomography (OPT) is a recently developed implementation of computed tomography (CT) techniques at optical frequencies. A series of 2D optical projections through a sample are generated at varying orientations, from which the 3D structure of the sample can be computationally reconstructed. OPT is especially suitable for samples from about 0.5 mm to 15 mm in size, which fills an important “imaging gap” between techniques such as confocal microscopy (useful for smaller samples) and large-sample methods such as fluorescence molecular tomography (FMT), x-ray CT or microscopic magnetic resonance imaging (μΜRI). OPT can function in both fluorescence and transmission modes.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملMotion corrected sensitivity encoded isotropic projection reconstruction (SNIPR) for whole-heart coronary MRA
Background As has been shown recently, the use of undersampled 3D projection reconstruction (3DPR) and image-based motion correction with 100% acquisition efficiency [1,2] enables highly accelerated coronary MRA (CMRA) with high isotropic resolution. However, streaking artifact from undersampling significantly reduces the apparent signal-to-noise ratio (SNR). Moreover, affine motion correction ...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کامل1 3 D Imaging of Nanomaterials by Discrete Tomography
The field of discrete tomography focuses on the reconstruction of samples that consist of only a few different materials. Ideally, a 3D reconstruction of such a sample should contain only one grey level for each of the compositions in the sample. By exploiting this property in the reconstruction algorithm, either the quality of the reconstruction can be improved significantly, or the number of ...
متن کامل