A comparison of four methods for distinguishing Doppler signals from gaseous and particulate emboli.

نویسندگان

  • J L Smith
  • D H Evans
  • P R Bell
  • A R Naylor
چکیده

BACKGROUND AND PURPOSE Many reports in the medical literature have proposed methods of differentiating between gaseous and particulate emboli detected with the use of transcranial Doppler ultrasound. The purpose of this study was to compare the previously published methods with our own sample volume length (SVL) parameter to assess the accuracy of each method in classifying emboli. METHODS A pure source of gaseous and particulate emboli was obtained from in vitro and in vivo studies, respectively, and recorded onto digital audiotape for off-line analysis. In total, 100 gaseous emboli and 215 particulate emboli were analyzed to measure four embolic parameters, namely, embolic duration, embolic velocity, relative signal intensity increase (measured embolic power [MEP]), and SVL of the embolic signal (= Duration x Velocity). Receiver operator characteristic analysis was used to assess the optimum threshold for each parameter to differentiate between particulate and gaseous emboli, and levels of sensitivity and specificity were calculated. RESULTS Embolic duration and velocity produced the poorest levels of sensitivity and specificity compared with the MEP and SVL parameters. The optimum thresholds for embolic duration and velocity were 35 ms and 1 m/s, respectively, which produced a sensitivity (specificity) of 85.1% (87%) and 87% (67%), respectively. The optimum MEP and SVL thresholds were 30 dB and 12.8 mm, respectively, which produced a sensitivity (specificity) of 86.5% (95%) and 93% (97%), respectively. The SVL and MEP parameters were compared statistically (chi 2) at chosen specificity values of 90%, 95%, 97%, 99%, and 100%, which showed that the SVL sensitivities were statistically greater than MEP sensitivities (P < 0.01). CONCLUSIONS SVL is the best parameter for differentiating between gaseous and particulate emboli but needs to be calculated with the use of a high-temporal-resolution spectral analyzer to measure embolic duration and velocity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.

BACKGROUND AND PURPOSE Doppler emboli detection is an established technique, but the nature of the underlying embolic material remains unclear. The intensity and spectral distribution of emboli signals could help to distinguish between signals arising from formed and gaseous emboli. We undertook this study to develop and evaluate a differentiation algorithm based on the spectral characteristics...

متن کامل

Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound ...

متن کامل

Transcranial Doppler Detection of Circulating Cerebral Emboli

Background: The identification of gaseous emboli using Doppler ultrasound was described as early as the 1960s. Recently it has been demonstrated that this method can also detect solid emboli such as thrombi and platelet aggregates. This may make this technology useful in a large number of patients with, or at risk of, embolic stroke. Summary of Review: Emboli appear as short-duration, high-inte...

متن کامل

Transcranial Doppler Detection of Circulating Cerebral Emboli

Background: The identification of gaseous emboli using Doppler ultrasound was described as early as the 1960s. Recently it has been demonstrated that this method can also detect solid emboli such as thrombi and platelet aggregates. This may make this technology useful in a large number of patients with, or at risk of, embolic stroke. Summary of Review: Emboli appear as short-duration, high-inte...

متن کامل

Transcranial Doppler Detection of Circulating Cerebral Emboli

Background: The identification of gaseous emboli using Doppler ultrasound was described as early as the 1960s. Recently it has been demonstrated that this method can also detect solid emboli such as thrombi and platelet aggregates. This may make this technology useful in a large number of patients with, or at risk of, embolic stroke. Summary of Review: Emboli appear as short-duration, high-inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 1998