Two-dimensional global and segmental longitudinal strain: are the results from software in different high-end ultrasound systems comparable?
نویسندگان
چکیده
To compare the peak global longitudinal myocardial strain (PGLS) and peak segmental longitudinal myocardial strain (PSLS) values by speckle-tracking echocardiography (STE) obtained using two different echocardiography devices. STE is an emerging quantitative ultrasound technique that allows an accurate evaluation of global and segmental myocardial function. However, there is a lack of standardization of the acquired data among different manufacturers. Sixty-three subjects, mean age 56.2±10.4 years, underwent complete echocardiographic studies with two different devices (Philips IE33 and General Electric VIVID E9) performed by the same operator. Thirty-one of them had known cardiac disease, with estimated left ventricular ejection fraction <50%, while 32 were free of any cardiovascular disease (control subjects). All images were digitally stored and analyzed using off-line post processing with QLAB 9 and EchoPAC 11 Software packages. PSLS and PGLS were calculated. A strong relationship between QLAB and EchoPAC was found for PGLS (r=0.91, P<0.001), PSLS-4 chamber (CH; r=0.79, P<0.001), PSLS-2CH (r=0.73, P<0.001), and PSLS-3CH (r=0.78, P<0.001) QLAB. Bland-Altman analysis showed absolute differences vs average of -0.16, -0.37, -0.21, and -0.16 for PGLS, PSLS-4CH, PSLS-2CH, and PSLS-apical long-axis views respectively. Segmental analysis showed a good agreement between the apical segments, whereas poor correlations were found for the basal segments. Receiver operating characteristic curve analysis showed that cutoff values for PGLS of -17.5 and -17.75% with Philips or GE systems gave a sensitivity and specificity of 93.5 and 87.5%, and 90 and 87.5%, respectively, in the discrimination of the patients from the controls. Both Philips and GE echo stations were found to give comparable results for PGLS, with approximately the same cutoff values, suggesting that their PGLS results may be interchangeable.
منابع مشابه
Normal range of left ventricular 2-dimensional strain: Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) study.
BACKGROUND To determine the normal range of left ventricular (LV) 2- dimensional (2-D) strain and vendor-specific differences, a multicenter prospective 2-D strain study endorsed by the Japanese Society of Echocardiography was conducted. METHODS AND RESULTS 2-D speckle tracking analysis was performed on 817 healthy subjects (age range, 0-88 years); the images included 3 LV short axis and 3 ap...
متن کاملComparative Myocardial Deformation in 3 Myocardial Layers in Mice by Speckle Tracking Echocardiography
BACKGROUND Speckle tracking echocardiography (STE) using dedicated high-resolution ultrasound is a relatively new technique that is useful in assessing myocardial deformation in 3 myocardial layers in small animals. However, comparative studies of STE parameters acquired from murine are limited. METHODS A high-resolution rodent ultrasound machine (VSI Vevo 2100) and a clinically validated ult...
متن کاملEvaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)
The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...
متن کاملComparison of two-dimensional strain analysis using vendor-independent and vendor-specific software in adult and pediatric patients
INTRODUCTION Two-dimensional strain analysis is a powerful analysis modality, however, clinical utilization has been limited by variability between different analysis systems and operators. We compared strain in adults and children using vendor-specific and vendor-independent software to evaluate variability. METHODS One hundred and ten subjects (50/110 pediatric, 80/110 normal left ventricul...
متن کاملEfficient Analysis of Plasmonic circuits using Differential Global Surface Impedance (DGSI) Model
Differential global surface impedance (DGSI) model, a rigorous approach, has been applied to the analysis of three dimensional plasmonic circuits. This model gives a global relation between the tangential electric field and the equivalent surface electric current on the boundary of an object. This approach helps one bring the unknowns to the boundary surface of an object and so avoid volumetric...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2015