Comparative Study Of Various Dissolved Gas Analysis Methods To Diagnose Transformer Faults
نویسندگان
چکیده
Dissolved gas analysis (DGA) is a reliable technique for detecting the presence of incipient fault conditions in oil immersed transformers. In this method the presence of certain key gases is monitored. The various analysis methods are : Rogers ratio, IEC ratio, Doernenburg, Duval triangle, key gas, artificial neural network (ANN) method. In this paper the various DGA methods are evaluated and compared. The comparative study is carried out from DGA data obtained from published papers. The key gases considered are hydrogen, methane, ethane, ethylene, acetylene. INTRODUCTION: Mineral oils is mixture of saturated hydro carbon paraffin whose general molecular formula is CnH2n+2 with ‘n ‘ in the range of 20-40. This oil acts as di electric medium and this heat transfer agent when used in transformers. During the occurrence of fault in the transformer, these gases are released within the unit. The rate of gas generation and its distribution indicates the severity of fault. Fault may occur due to overheating, arcing, partial discharge, over heating in cellulose, etc. The fault gases are methane(CH4),ethane (C2H6), ethylene (C2H4),acetylene(C2H2), hydrogen(H2),carbon monoxide(CO),carbon di oxide(CO2).non fault gasses are nitrogen(N2),Oxygen(O2). Depending up on the fault gas there are several technique to analyse the type if transformer fault. METHODOLOGY: The insulating oils breakdown to release small quantity of gases up on occurrence of fault. It is possible to distinguish fault such as partial discharge (corona), overheating, arcing, by means of DGA 1. Roger ratio method: In this method four ratio CH4/H2, C2H6/CH4, C2H4/C2H6 and C2H2/C2H4 are utilised. The code number that is generated can be related to a diagnostic interpretation as shown in Table 1,2 & 3. Table(1): 2. IEC method: This method similar to Roger’s ratio method except that the ratios C2H6/CH4 is excluded as it indicates only a limited range of decomposition. A detailed description of IEC method shown in table(4).
منابع مشابه
Fuzzy-Logic Applications in Transformer Diagnosis Using Individual and Total Dissolved Key Gas Concentrations
The gases generated in oil filled transformer can be used for determination of incipient faults. Dissolved gas analysis (DGA) of transformer oil has been one of the most power full methods to detect the faults. The various methods such as liquid chromatography, acoustic analysis, and transformer function techniques are require some experience to interpret observations. The researchers have used...
متن کاملTransformer Fault Diagnosis Based on Ontology and Dissolved Gas Analysis
This paper proposes an ontology model for accurate and efficient transformer fault diagnosis using an explicit, formal and machine-readable format. The model makes use of ontology to represent formally faults and their features such as causes, symptoms, effects, which form a transformer fault diagnosis knowledge base. Moreover, the model can be employed to exchange and reason information for tr...
متن کاملIntuitionistic Fuzzy Expert System based Fault Diagnosis using Dissolved Gas Analysis for Power Transformer
In transformer fault diagnosis, dissolved gas analysis (DGA) is been widely employed for a long period and numerous methods have been innovated to interpret its results. Still in some cases it fails to identify the corresponding faults. Due to the limitation of training data and non-linearity, the estimation of key-gas ratio in the transformer oil becomes more complicated. This paper presents I...
متن کاملArtificial Neural Networks for Power Transformers Fault Diagnosis Based on IEC Code Using Dissolved Gas Analysis
Transformer is the main important equipment in electrical power system. Early stage detection of the transformer faults has great economic significance because it considered expensive equipment and it helps to maintain the continuous operation of the electrical power system. Transformer oil is used for two main purposes, one for insulating liquid and the other for cooling. Some physicalchemical...
متن کاملCanonical Correlation Between Partial Discharges and Gas Formation in Transformer Oil Paper Insulation
Dissolved gas analysis (DGA) has been widely applied to diagnose internal faults in transformer insulation systems. However, the accuracy of DGA technique is limited because of the lack of positive correlation of the fault-identifying gases with faults found in power transformers. This paper presents a laboratory study on the correlation between oil dissolved gas formation and partial discharge...
متن کاملFuzzy Decision on Transformer Fault Diagnosis using Dissolved Gas Analysis and IEC Ratio Codes
This paper emphasizes on the use of fuzzy approach in dealing with the incipient fault conditions of power transformer. DGA (Dissolved Gas in Oil Analysis) cannot provide better fault diagnosis results when multiple faults are involved. The boundary values specified by the ratio methods are of limited concern .Considering the limitations of convergence of the conventional neural networks in the...