Metal ion levels in patients with a lumbar metal-on-metal total disc replacement: should we be concerned?

نویسندگان

  • P Bisseling
  • D J Zeilstra
  • A M Hol
  • J L C van Susante
چکیده

The purpose of this study was to evaluate whether concerns about the release of metal ions in metal-on-metal total hip replacements (THR) should be extended to patients with metal-bearing total disc replacements (TDR). Cobalt and chromium levels in whole blood and serum were measured in ten patients with a single-level TDR after a mean follow-up of 34.5 months (13 to 61) using inductively-coupled plasma mass spectrometry. These metal ion levels were compared with pre-operative control levels in 81 patients and with metal ion levels 12 months after metal-on-metal THR (n = 21) and resurfacing hip replacement (n = 36). Flexion-extension radiographs were used to verify movement of the TDR. Cobalt levels in whole blood and serum were significantly lower in the TDR group than in either the THR (p = 0.007) or the resurfacing group (p < 0.001). Both chromium levels were also significantly lower after TDR versus hip resurfacing (p < 0.001), whereas compared with THR this difference was only significant for serum levels (p = 0.008). All metal ion levels in the THR and resurfacing groups were significantly higher than in the control group (p < 0.001). In the TDR group only cobalt in whole blood appeared to be significantly higher (p < 0.001). The median range of movement of the TDR was 15.5° (10° to 22°). These results suggest that there is minimal cause for concern about high metal ion concentrations after TDR, as the levels appear to be only moderately elevated. However, spinal surgeons using a metal-on-metal TDR should still be aware of concerns expressed in the hip replacement literature about toxicity from elevated metal ion levels, and inform their patients appropriately.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty-Preliminary results of a prospective five year study after two years of follow-up

BACKGROUND Metal-on-metal hip resurfacing is an alternative to metal-on-metal total hip arthroplasty, especially for young and physically active patients. However, wear which might be detected by increased serum ion levels is a matter of concern. METHODS The aims of this preliminary study were to determine the raise of metal ion levels at 2-years follow-up in a prospective setting and to eval...

متن کامل

Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study.

Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the se...

متن کامل

Prospective, randomized trial of metal-on-metal artificial lumbar disc replacement: initial results for treatment of discogenic pain.

STUDY DESIGN This study presents data on 67 patients from 2 study sites involved in the multicenter, prospective, randomized, controlled investigational device exemption study of FlexiCore artificial disc replacement versus fusion with a 2-year follow-up. OBJECTIVE To compare the outcomes achieved with the FlexiCore disc replacement versus standard circumferential fusion for the treatment of ...

متن کامل

Worse health-related quality of life and hip function in female patients with elevated chromium levels

Background and purpose - Blood metal ion levels can be an indicator for detecting implant failure in metal-on-metal (MoM) hip arthroplasties. Little is known about the effect of bilateral MoM implants on metal ion levels and patient-reported outcomes. We compared unilateral patients and bilateral patients with either an ASR hip resurfacing (HR) or an ASR XL total hip replacement (THR) and inves...

متن کامل

Ion Release from Metal-on-metal Hip Resurfacing Implants Does Not Differ from Standard Metal-on-metal Total Hip Replacement

STANDARD METAL-ON-METAL TOTAL HIP REPLACEMENT *Moroni A, **Savarino L, *Cadossi M, **Greco M, **Baldini N, *Giannini S * Rizzoli Orthopaedic Institute, Bologna, Italy **Laboratory for Pathophysiology of Orthopaedic Implants, Rizzoli Orthopaedic Institute, Bologna, Italy [email protected] INTRODUCTION Modern metal-on-metal (MOM) hip resurfacing has been introduced as a less invasive method of join...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 7  شماره 

صفحات  -

تاریخ انتشار 2011