CORR Insights(®): implant design variations in reverse total shoulder arthroplasty influence the required deltoid force and resultant joint load.

نویسنده

  • Robert Z Tashjian
چکیده

BACKGROUND Reverse total shoulder arthroplasty (RTSA) is widely used; however, the effects of RTSA geometric parameters on joint and muscle loading, which strongly influence implant survivorship and long-term function, are not well understood. By investigating these parameters, it should be possible to objectively optimize RTSA design and implantation technique. QUESTIONS/PURPOSES The purposes of this study were to evaluate the effect of RTSA implant design parameters on (1) the deltoid muscle forces required to produce abduction, and (2) the magnitude of joint load and (3) the loading angle throughout this motion. We also sought to determine how these parameters interacted. METHODS Seven cadaveric shoulders were tested using a muscle load-driven in vitro simulator to achieve repeatable motions. The effects of three implant parameters-humeral lateralization (0, 5, 10 mm), polyethylene thickness (3, 6, 9 mm), and glenosphere lateralization (0, 5, 10 mm)-were assessed for the three outcomes: deltoid muscle force required to produce abduction, magnitude of joint load, and joint loading angle throughout abduction. RESULTS Increasing humeral lateralization decreased deltoid forces required for active abduction (0 mm: 68% ± 8% [95% CI, 60%-76% body weight (BW)]; 10 mm: 65% ± 8% [95% CI, 58%-72 % BW]; p = 0.022). Increasing glenosphere lateralization increased deltoid force (0 mm: 61% ± 8% [95% CI, 55%-68% BW]; 10 mm: 70% ± 11% [95% CI, 60%-81% BW]; p = 0.007) and joint loads (0 mm: 53% ± 8% [95% CI, 46%-61% BW]; 10 mm: 70% ± 10% [95% CI, 61%-79% BW]; p < 0.001). Increasing polyethylene cup thickness increased deltoid force (3 mm: 65% ± 8% [95% CI, 56%-73% BW]; 9 mm: 68% ± 8% [95% CI, 61%-75% BW]; p = 0.03) and joint load (3 mm: 60% ± 8% [95% CI, 53%-67% BW]; 9 mm: 64% ± 10% [95% CI, 56%-72% BW]; p = 0.034). CONCLUSIONS Humeral lateralization was the only parameter that improved joint and muscle loading, whereas glenosphere lateralization resulted in increased loads. Humeral lateralization may be a useful implant parameter in countering some of the negative effects of glenosphere lateralization, but this should not be considered the sole solution for the negative effects of glenosphere lateralization. Overstuffing the articulation with progressively thicker humeral polyethylene inserts produced some adverse effects on deltoid muscle and joint loading. CLINICAL RELEVANCE This systematic evaluation has determined that glenosphere lateralization produces marked negative effects on loading outcomes; however, the importance of avoiding scapular notching may outweigh these effects. Humeral lateralization's ability to decrease the effects of glenosphere lateralization was promising but further investigations are required to determine the effects of combined lateralization on functional outcomes including range of motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of subscapularis repair in reverse total shoulder arthroplasty.

BACKGROUND Controversy surrounds the role of the sub- scapularis (SSC) in reverse shoulder arthroplasty (rTSA) and the need for repair, if possible, at the conclusion of the procedure. QUESTIONS AND PURPOSE: Some investigators have concluded that an intact SSC is critical for stability; others have found no such correlation. What factors should be part of the decision-making matrix on SSC manag...

متن کامل

Effect of lateral offset center of rotation in reverse total shoulder arthroplasty: a biomechanical study.

BACKGROUND Lateral offset center of rotation (COR) reduces the incidence of scapular notching and potentially increases external rotation range of motion (ROM) after reverse total shoulder arthroplasty (rTSA). The purpose of this study was to determine the biomechanical effects of changing COR on abduction and external rotation ROM, deltoid abduction force, and joint stability. MATERIALS AND ...

متن کامل

Revision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?

Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...

متن کامل

Muscle force and excursion requirements and moment arm analysis of a posterior-superior offset reverse total shoulder prosthesis.

Current reverse total shoulder arthroplasty prosthesis designs do not permit offset of the humerus in the sagittal plane. Posteriorly shifting the humerus has the theoretical benefit of lengthening the infraspinatus and teres minor muscles and their external rotation moment arms, thereby improving the tension and efficiency of each external rotator and subsequently requiring each muscle to prod...

متن کامل

Evolution of the reverse total shoulder prosthesis.

Over the last decade, reverse total shoulder arthroplasty has gained significant popularity due to its ability to address difficult reconstructive shoulder problems that could not be adequately treated in the past. The concept of the reverse shoulder prosthesis was introduced in the 1970s, but the initial attempts were associated with high complication and implant failure rates. The pioneering ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 473 12  شماره 

صفحات  -

تاریخ انتشار 2015