Cost-utility analysis of percutaneous mitral valve repair in inoperable patients with functional mitral regurgitation in German settings
نویسندگان
چکیده
BACKGROUND To determine the cost-effectiveness of the percutaneous mitral valve repair (PMVR) using Carillon® Mitral Contour System® (Cardiac Dimensions Inc., Kirkland, WA, USA) in patients with congestive heart failure accompanied by moderate to severe functional mitral regurgitation (FMR) compared to the prolongation of optimal medical treatment (OMT). METHODS Cost-utility analysis using a combination of a decision tree and Markov process was performed. The clinical effectiveness was determined based on the results of the Transcatheter Implantation of Carillon Mitral Annuloplasty Device (TITAN) trial. The mean age of the target population was 62 years, 77% of the patients were males, 64% of the patients had severe FMR and all patients had New York Heart Association functional class III. The epidemiological, cost and utility data were derived from the literature. The analysis was performed from the German statutory health insurance perspective over 10-year time horizon. RESULTS Over 10 years, the total cost was €36,785 in the PMVR arm and €18,944 in the OMT arm. However, PMVR provided additional benefits to patients with an 1.15 incremental quality-adjusted life years (QALY) and an 1.41 incremental life years. The percutaneous procedure was cost-effective in comparison to OMT with an incremental cost-effectiveness ratio of €15,533/QALY. Results were robust in the deterministic sensitivity analysis. In the probabilistic sensitivity analysis with a willingness-to-pay threshold of €35,000/QALY, PMVR had a 84 % probability of being cost-effective. CONCLUSIONS Percutaneous mitral valve repair may be cost-effective in inoperable patients with FMR due to heart failure.
منابع مشابه
SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY
BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...
متن کاملبررسی عوامل موثر در افزایش سطح دریچه و پیدایش نارسایی میترال بعد از بالون میترال والولوپلاستی در 110 بیمار در مجتمع بیمارستانی امام خمینی
Background: Percutaneous Transeptal Mitral Commisurotomy (PTMC) has been used in treating mitral stenosis with variable success, its main complication being mitral incompetence. There is a need to define the subgroup of the patients who benefit mostly from the procedure. Methods: We studied 110 patients (age 17 to 60 years mean 33.2) with mitral stenosis. PTMC was performed though femoral vein....
متن کاملاثر PercutaneousCoronary Intervention Elective بر بهبودی نارسایی ایسکمیک میترال
Introdution: Ischemic mitral regurgitation (IMR) remains one of the most complex and unresolved aspects of ischemic heart disease that the impact of percutaneous coronary intervention (PCI) on improvement of intensity of ischemic mitral regurgitation is not well clarified. Patients with coronary artery diseases and ischemic mitral regurgitation have a worse prognosis than the patients with coro...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملPercutaneous treatment of mitral regurgitation with MitraClip device
The percutaneous edge-to-edge repair of mitral regurgitation with a MitraClip device has been recently approved in Europe. The results of the randomized EVEREST II study showed a favourable safety profile of the technique. However, the efficacy in terms of regurgitation reduction in a population with predominantly degenerative mitral disease was inferior as compared to the results of convention...
متن کامل