A Comparative Study of Shaping Ability of four Rotary Systems.
نویسندگان
چکیده
PURPOSE This study compared the cutting area, instrumentation time, root canal anatomy preservation and non-instrumented areas obtained by F360(®), Mtwo(®), RaCe(®) and Hyflex(®) files with ISO size 35. MATERIAL AND METHODS 120 teeth with a single straight root and root canal were divided into 4 groups. Working length was calculated by using X-rays. The teeth were sectioned with a handpiece and a diamond disc, and the sections were observed with Nikon SMZ-2T stereoscopic microscope and an Intralux 4000-1 light source. The groups were adjusted with a preoperative analysis with AutoCAD. The teeth were reconstructed by a #10 K-File and epoxy glue. Each group was instrumented with one of the four file systems. The instrumentation time was calculated with a 1/100 second chronometer. The area of the thirds and root canal anatomy preservation were analyzed with AutoCAD 2013 and the non-instrumented areas with AutoCAD 2013 and SMZ-2T stereoscopic microscope. The statistical analysis was made with Levene's Test, ANOVA, Bonferroni Test and Pearson´s Chi-square. RESULTS Equal variances were shown by Levene's Test (P > 0.05). ANOVA (P > 0.05) showed the absence of significant differences. There were significant differences in the instrumentation time (P < 0.05). For root canal anatomy preservation and non-instrumented areas, there were no significant differences between all systems (P > 0.05). CONCLUSIONS The 4 different rotary systems produced similar cutting area, root canal anatomy preservation and non-instrumented areas. Regarding instrumentation time, F360(®) was the fastest system statistically.
منابع مشابه
Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study)
Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study) Dr. M.H. Zarrabi* - Dr. A. Talati** - Dr. S. Moradi** - Dr. L. Shakeri*** * - Associate Professor and Chief of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Scien...
متن کاملShaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth
Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...
متن کاملComparison of canal transportation after preparation by 3 different rotary systems
Comparison of canal transportation after preparation by 3 different rotary systems Dr. Javidi, M.* - Dr. Zarei, M.* - Dr. Vatanpour, M.** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Tehran Azad University. Abstract Background & Aim: Cleaning and shaping has been recogni...
متن کاملمقایسه ترانسپورتیشن دو سیستم روتاری رسیپروک و نئولیکس در کانالهای انحنادار ریشه دندان توسط توموگرافی کامپیوتری با اشعه مخروطی
Background and Objective: The preparation of the root canal (i.e., cleaning and shaping) is the main step in the endodontic treatment. The nickel-titanium rotary files result in fewer errors during the preparation of curved canals. This study aimed to compare the transportation of Neolix and Reciproc rotary systems in curved canals using cone beam computed tomography (CBCT). Materials and Meth...
متن کاملComparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals
Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...
متن کاملShaping potential of manual NiTi K-File and rotary ProTaper and analyzing the final outcome of shaped canals using CT.
AIM To assess and compare the shaping potential of manual NiTi K-files and Rotary ProTaper instruments in narrow canals using CT. OBJECTIVE To assess the shaping potential of manual NiTi K-files and Rotary ProTaper and analyzing the final outcome of shaped canals using CT and determining different variables, like • Working time • Change in volume • Change in cross-sectional area. MATERIALS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta stomatologica Croatica
دوره 49 4 شماره
صفحات -
تاریخ انتشار 2015