A SILICON PHOTODIODE ARRAY DETECTOR COVERING A LARGE SOLID ANGLE FOR FLUORESCENCE EXAFS MEASUREMENTS FROM 2 TO 25 keV

نویسندگان

  • A. Retournard
  • M. Loos
  • I. Ascone
  • J. Goulon
  • M. Lemonnier
  • R. Cortes
چکیده

A Si-photodiode array detector operated in the photovoltaic mode is shown to offer several advantages over other fluorescence detectors: high efficiency, perfect linearity of the response, vacuum compatibility for soft X-ray measurements, absence of gas and voltage supplies. Low temperature cooling down to 120°c is needed in order to decrease the dark current and thermal noise of the shunt resistance.Typica1 spectra recorded on a dilute cytochrome c solution and on a liquid which is strongly absorbing in the soft X-ray range i.e. c2c14* are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double-Layer Silicon PIN Photodiode X-Ray Detector for a Future X-ray Timing Mission

A double-layer silicon detector consisting of two 500μm-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1–30 keV with an effective area of 6 mm. The detector performs best at −35 ◦C with an energy resolution of 220 eV (FWHM, full width at half maximum) at 5.9 keV, and is able to operate at room...

متن کامل

A liquid-helium cooled large-area silicon PIN photodiode x-ray detector

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose firststage JFET has been cooled. The operating temperature of the JFET has been varied separately and optimized. The xand γ-ray energy spectra for an Am source have been measured with the photodiode operated at 13 K. An energy resolutio...

متن کامل

Advances in array detectors for X-ray diffraction techniques.

Improved focal plane array detector systems are described which can provide improved readout speeds, random addressing and even be employed to simultaneously measure position, intensity and energy. This latter capability promises to rekindle interests in Laue techniques. Simulations of three varieties of foil mask spectrometer in both on- and off-axis configurations indicate that systems of sta...

متن کامل

Silicon Lithium Detectors for Synchrotron Energy Dispersive X-Ray Fluorescence Spectroscopy

Introduction Detector description and its principle of operation Detector module. Detector Features and its Performance EDXRF of Fe 55 Spectrum Detector comparison with Silicon Drift Detector SDD Concluding remarks References A Silicon Lithium Si(Li) detector is presented. The detector structure and its working principle are explained. The detector is cooled to 77o K by liquid Nitrogen. The det...

متن کامل

Low Energy Measurement of the 18F(p,α)15O Cross Section at TRIUMF

An experiment to measure the 18F(p,α)15O cross section at low centre of mass energies has been performed with the TRIUMF-UK Detector Array (TUDA) facility at TRIUMF. Measurements of the 18F(p,α)15O reaction rate at four separate centre of mass energies; 665 keV, 430 keV, 330 keV and 250 keV, were carried out. The main goal of the experiment was the measurement of the 18F(p,α)15O cross section b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017