Three-dimensional analysis of the tibial resection plane relative to the arthritic tibial plateau in total knee arthroplasty
نویسندگان
چکیده
BACKGROUND Kinematically aligned total knee arthroplasty strives to correct the arthritic deformity by restoring the native tibial joint line. However, the precision of such surgical correction needs to be quantified in order to reduce recuts of the resection and to design assisting instrumentation. This study describes a method for novel three-dimensional analysis of tibial resection parameters in total knee arthroplasty. Pre-operative versus post-operative differences in the slopes of the varus-valgus and flexion-extension planes and the proximal-distal level between the tibia resection and the arthritic tibial joint line can reliably be measured using the three-dimensional models of the tibia and fibula. This work uses the proposed comparison method to determine the parameters for resecting the tibia in kinematically aligned total knee arthroplasty. METHODS Three-dimensional shape registration was performed between arthritic surface models segmented from pre-operative magnetic resonance imaging scans and resected surface models segmented from post-operative computed tomography scans. Mean, standard deviation and 95% confidence intervals were determined for all measurements. RESULTS: Results indicate that kinematically aligned total knee arthroplasty consistently corrects the varus deformity and restores the slope of the flexion-extension plane and the proximal-distal level of the arthritic tibial joint line. The slope of the varus-valgus plane is most precisely associated with the overall arthritic slope after approximately 3° of correction and the posterior slope is biased towards the overall arthritic plateau, though less precisely than the varus correlation. CONCLUSIONS Use of this analysis on a larger population can quantify the effectiveness of the tibial resection for correcting pathologies, potentially reduce imprecisions in the surgical technique, and enable development of instrumentation that reduces the risk of resection recuts. The kinematic alignment technique consistently corrects varus deformities.
منابع مشابه
Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...
متن کاملAcute Primary Total Knee Arthroplasty for Proximal Tibial Fractures in Elderly
Background: Proximal tibial fractures in elderly patients with osteoporosis or knee osteoarthritis (OA) are challengingcases. In the current study, we present our experience with uncommon acute primary total knee arthroplasty (PTKA)in this patient population.Methods: PTKAs were performed following proximal tibial fractures in 30 consecutive patients over 60 years of agewith osteoporosis or knee...
متن کاملUnicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?
Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis. Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...
متن کاملThe natural history of spontaneous osteonecrosis of the medial tibial plateau.
The natural history of spontaneous osteonecrosis of the medial tibial plateau remains controversial and incomplete. We have studied 21 patients (aged between 53 and 77 years) with clinical and scintigraphic features of spontaneous osteonecrosis of the medial tibial plateau who were observed prospectively for at least three years (37 months to 8.5 years). The mean duration of follow-up was 5.6 y...
متن کاملThe offset of the tibial shaft from the tibial plateau in Chinese people.
BACKGROUND Long-stem tibial components are available for complex primary and revision total knee arthroplasties. Most of the stems' designs are based on anatomic data from Western populations. We conducted a morphologic study to determine the relationship of the tibial shaft to the tibial plateau in Chinese people. METHODS We included knees from fifty Chinese individuals (twenty-five females ...
متن کامل