Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in patients with left ventricular dysfunction.

نویسندگان

  • Ichiro Matsunari
  • Hirofumi Aoki
  • Yusuke Nomura
  • Nozomi Takeda
  • Wei-Ping Chen
  • Junichi Taki
  • Kenichi Nakajima
  • Stephan G Nekolla
  • Seigo Kinuya
  • Kouji Kajinami
چکیده

BACKGROUND Although both (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging and (11)C-hydroxyephedrine ((11)C-HED) positron emission tomography (PET) are used for assessing cardiac sympathetic innervation, their relationship remains unknown. The aims were to determine whether (123)I-MIBG parameters such as heart-to-mediastinum ratio (H/M) are associated with quantitative measures by (11)C-HED PET and to compare image quality, defect size, and location between (123)I-MIBG single-photon emission computed tomography (SPECT) and (11)C-HED PET. METHODS AND RESULTS Twenty-one patients (mean left ventricular ejection fraction, 39 ± 15%) underwent (123)I-MIBG imaging and (11)C-HED PET. Early (15-minute), late (3-hour) H/M, and washout rate (WR) were calculated for (123)I-MIBG. Myocardial retention and WR was calculated for (11)C-HED. Using a polar map approach, defect was defined as the area with relative activity <60% of the maximum. Both the early (r=0.76) and late (r=0.84) (123)I-MIBG H/M were correlated with (11)C-HED retention. (123)I-MIBG WR was correlated with (11)C-HED WR (r=0.57). Defect size could not be measured in 3 patients because of poor quality (123)I-MIBG SPECT, whereas (11)C-HED defect was measurable in all patients. Although defect size measured by early or late (123)I-MIBG SPECT was closely correlated with that by (11)C-HED PET (early: r=0.94; late: r=0.88), the late (123)I-MIBG overestimated defect size particularly in the inferior and septal regions. CONCLUSIONS (123)I-MIBG H/M gives a reliable estimate of cardiac sympathetic innervation as measured by (11)C-HED PET. Furthermore, despite the close correlation in defect size, (11)C-HED PET appears to be more suitable for assessing regional abnormalities than does (123)I-MIBG SPECT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between altered sympathetic innervation, oxidative metabolism and contractile function in the cardiomyopathic human heart; a non-invasive study using positron emission tomography.

AIMS To identify functional and metabolic correlates of impaired presynaptic sympathetic innervation in the cardiomyopathic human heart using non-invasive correlative imaging. METHODS AND RESULTS In 10 patients with idiopathic dilated cardiomyopathy, presynaptic catecholamine uptake sites were quantified by positron emission tomography with C-11 hydroxyephedrine. Oxidative metabolism was meas...

متن کامل

Comparison of iodine-123 metaiodobenzylguanidine (MIBG) scan and [18F]fluorodeoxyglucose positron emission tomography to evaluate response after iodine-131 MIBG therapy for relapsed neuroblastoma.

PURPOSE Children with relapsed neuroblastoma have poor survival. It is crucial to have a reliable method for evaluating functional response to new therapies. In this study, we compared two functional imaging modalities for neuroblastoma: metaiodobenzylguanidine (MIBG) scan for uptake by the norepinephrine transporter and [(18)F]fluorodeoxyglucose positron emission tomography (FDG-PET) uptake fo...

متن کامل

Regional patterns of myocardial sympathetic denervation in dilated cardiomyopathy: an analysis using carbon-11 hydroxyephedrine and positron emission tomography.

OBJECTIVE To assess presynaptic function of cardiac autonomic innervation in patients with advanced congestive heart failure using positron emission tomography (PET) and the recently developed radiolabelled catecholamine analogue carbon-11 hydroxyephedrine (HED) as a marker for neuronal catecholamine uptake function. DESIGN AND PATIENTS 29 patients suffering from dilated cardiomyopathy with m...

متن کامل

Molecular imaging in heart failure patients

This review focuses on molecular imaging using various radioligands for the tissue characterization of patients with heart failure. 123I-labeled metaiodobenzylguanidine (MIBG), as a marker of adrenergic neuron function, plays an important role in risk stratification in heart failure and may be useful for predicting fatal arrhythmias that may require implantable cardioverter-defibrillator treatm...

متن کامل

Prediction of all-cause death using 11C-hydroxyephedrine positron emission tomography in Japanese patients with left ventricular dysfunction

OBJECTIVES The aim of this study was to determine whether (11)C-hydroxyephedrine ((11)C-HED) can predict adverse events including all-cause death in Japanese patients with left ventricular (LV) dysfunction. BACKGROUND Although (11)C-HED PET has been used to assess cardiac sympathetic innervation in various disease conditions, data on their prognostic value are limited. METHODS Sixty patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 3 5  شماره 

صفحات  -

تاریخ انتشار 2010