Three-dimensional turbo spin-echo sequence versus conventional two-dimensional turbo spin-echo sequences in the evaluation of lumbar intervertebral discs
نویسندگان
چکیده
Objective. The aim of this study was to evaluate the efficacy of a three-dimensional (3D) turbo spin-echo (TSE) sequence for determining lumbar disc protrusions, and to compare the findings with those of conventional two-dimensional (2D) TSE sequences and reveal the interobserver and intermethod agreements of both sequences. Methods. A total of 127 discs from 84 patients were evaluated by three radiologists. Conventional 2D TSE images and 3D TSE images were independently interpreted with regard to disc pathology and herniation zones and were scored for the degree of spinal stenosis and lumbar neural foraminal stenosis by the three reviewers. To evaluate the lumbar discs, areas of protrusion or extrusion were classified. Interobserver and intermethod reliabilities were calculated using Krippendorff’s alpha (Kα) test. Results. Lumbar disc pathology identification was similar between the 2D TSE and 3D TSE sequences. Interobserver agreements were better for 3D TSE than 2D TSE in the evaluation of disc hernias (Kα ratio; 0.965 vs. 0.944), herniation zones (Kα ratio; 0.894 vs. 0.847), and foraminal narrowing (Kα ratio; 0.965 vs. 0.924). Both 2D and 3D TSE had 100% sensitivity for disc pathologies and spinal stenosis, 81% sensitivity for herniation zones, and 92.5% sensitivity for foraminal stenosis in only operated patients. Conclusions. The 3D TSE sequence was comparable to conventional magnetic resonance imaging (MRI) sequences in the evaluation of lumbar disc herniation. This approach can be used in radiology departments either alone or combined with routine MRI for lumbar disc hernias as a diagnostic sequence and an approach to overcome problems.
منابع مشابه
Lumbar degenerative disk disease: prospective comparison of conventional T2-weighted spin-echo imaging and T2-weighted rapid acquisition relaxation-enhanced imaging.
PURPOSE To compare conventional T2-weighted spin-echo imaging with a rapid acquisition relaxation enhanced (RARE) technique in the routine evaluation of lumbar degenerative disk disease. METHODS Thirty consecutive patients referred for evaluation of the lumbar spine for suspected degenerative disk disease were evaluated with sagittal and axial T1-weighted spin-echo, conventional T2-weighted s...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملComparison of MR pulse sequences in the detection of multiple sclerosis lesions.
PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...
متن کاملStaging urinary bladder cancer: value of T1-weighted three-dimensional magnetization prepared-rapid gradient-echo and two-dimensional spin-echo sequences.
OBJECTIVE The purpose of this study was to evaluate a magnetization prepared-rapid gradient-echo (MP-RAGE) sequence as a three-dimensional T1-weighted MR imaging technique for staging urinary bladder cancer and to compare this technique with a commonly used two-dimensional T1-weighted spin-echo sequence technique. SUBJECTS AND METHODS For 28 consecutive patients with urinary bladder cancer, M...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کامل