Baseline correction of phase-contrast images in congenital cardiovascular magnetic resonance
نویسندگان
چکیده
BACKGROUND One potential source of error in phase contrast (PC) congenital CMR flow measurements is caused by phase offsets due to local non-compensated eddy currents. Phantom correction of these phase offset errors has been shown to result in more accurate measurements of blood flow in adults with structurally normal hearts. We report the effect of phantom correction on PC flow measurements at a clinical congenital CMR program. RESULTS Flow was measured in the ascending aorta, main pulmonary artery, and right and left pulmonary arteries as clinically indicated, and additional values such as Qp/Qs were derived from these measurements. Phantom correction in our study population of 149 patients resulted in clinically significant changes in 13% to 48% of these phase-contrast measurements in patients with known or suspected heart disease. Overall, 640 measurements or calculated values were analyzed, and clinically significant changes were found in 31%. Larger vessels were associated with greater phase offset errors, with 22% of the changes in PC flow measurements attributed to the size of the vessel measured. In patients with structurally normal hearts, the pulmonary-to-systemic flow ratio after phantom correction was closer to 1.0 than before phantom correction. There was no significant difference in the effect of phantom correction for patients with tetralogy of Fallot as compared to the group as a whole. CONCLUSIONS Phantom correction often resulted in clinically significant changes in PC blood flow measurements in patients with known or suspected congenital heart disease. In laboratories performing clinical CMR with suspected phase offset errors of significance, the routine use of phantom correction for PC flow measurements should be considered.
منابع مشابه
Baseline correction of phase contrast images improves quantification of blood flow in the great vessels.
PURPOSE Phase-contrast Cardiovascular Magnetic Resonance Imaging (CMR) generally requires the analysis of stationary tissue adjacent to a blood vessel to serve as a baseline reference for zero velocity. However, for the heart and great vessels, there is often no stationary tissue immediately adjacent to the vessel. Consequently, uncorrected velocity offsets may introduce substantial errors in f...
متن کاملNonlinear self-calibrated phase contrast correction in pediatric and congenital cardiovascular magnetic resonance imaging
Background Phase contrast (PC) MR flow measurements are affected by phase offset errors due to local eddy currents. Performing error correction using an MR phantom prolongs each CMR study and can impede scanner workflow. Recently, a novel post-hoc nonlinear self-calibrated PC correction algorithm has been developed that can be applied to PC flow data, with equivalence to phantom correction and ...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملMagnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملCorrection of phase offset errors in cardiovascular magnetic resonance using background subtraction from stationary tissue
Introduction Phase offset errors from local eddy currents can lead to significant errors in flow assessment on clinical cardiovascular magnetic resonance (CMR) examinations. Phantom correction for phase contrast (PC) errors appears to improve accuracy in flow assessment, but requires additional time and is not free from technical limitations. Background subtraction using a region of stationary ...
متن کامل