Evaluation of right and left ventricular function by quantitative blood-pool SPECT (QBS): comparison with conventional methods and quantitative gated SPECT (QGS).
نویسندگان
چکیده
Though quantitative ECG-gated blood-pool SPECT (QBS) has become a popular tool in research settings, more verification is necessary for its utilization in clinical medicine. To evaluate the reliability of the measurements of left and right ventricular functions with QBS, we performed QBS, as well as first-pass pool (FPP) and ECG-gated blood-pool (GBP) studies on planar images in 41 patients and 8 healthy volunteers. Quantitative ECG-gated myocardial perfusion SPECT (QGS) was also performed in 30 of 49 subjects. First, we assessed the reproducibility of the measurements of left and right ventricular ejection fraction (LVEF, RVEF) and left and right ventricular end-diastolic volume (LVEDV, RVEDV) with QBS. Second, LVEF and RVEF obtained from QBS were compared with those from FPP and GBP, respectively. Third, LVEF and LVEDV obtained from QBS were compared with those from QGS, respectively. The intra- and inter-observer reproducibilities were excellent for LVEF, LVEDV, RVEF and RVEDV measured with QBS (r = 0.88 to 0.96, p < 0.01), while the biases in the measurements of RVEF and RVEDV were relatively large. LVEF obtained from QBS correlated significantly with those from FPP and GBP, while RVEF from QBS did not. LVEF and LVEDV obtained from QBS were significantly correlated with those from QGS, but the regression lines were not close to the lines of identity. In conclusion, the measurements of LVEF and LVEDV with QBS have good reproducibility and are useful clinically, while those of RVEF and RVEDV are less useful compared with LVEF and LVEDV. The algorithm of QBS for the measurements of RVEF and RVEDV remains to be improved.
منابع مشابه
Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software
Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...
متن کامل[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].
UNLABELLED Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS Thirty-fiv...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 20 8 شماره
صفحات -
تاریخ انتشار 2006