Light-Induced Thickening of Photoreceptor Outer Segment Layer Detected by Ultra-High Resolution OCT Imaging
نویسندگان
چکیده
PURPOSE We examined if light induces changes in the retinal structure that can be observed using optical coherence tomography (OCT). METHODS Normal C57BL/6J mice (age 3-6 months) adapted to either room light (15 minutes to ∼5 hours, 50-500 lux) or darkness (overnight) were imaged using a Bioptigen UHR-OCT system. Confocal histologic images were obtained from mice killed under light- or dark-adapted conditions. RESULTS The OCT image of eyes adapted to room light exhibited significant increases (6.1 ± 0.8 μm, n = 13) in total retina thickness compared to the same eyes after overnight dark adaptation. These light-adapted retinal thickness changes occurred mainly in the outer retina, with the development of a hyporeflective band between the RPE and photoreceptor-tip layers. Histologic analysis revealed a light-evoked elongation between the outer limiting membrane and Bruch's membrane from 45.8 ± 1.7 μm in the dark (n = 5) to 52.1 ± 3.7 μm (n = 5) in the light. Light-adapted retinas showed an increase of actin staining in RPE apical microvilli at the same location as the hyporeflective band observed in OCT images. Elongation of the outer retina could be detected even with brief light exposures, increasing 2.1 ± 0.3 μm after 15 minutes (n = 9), and 4.1 ± 1.0 μm after 2 hours (n = 6). Conversely, dark-adaptation caused outer retinal shortening of 1.4 ± 0.4 μm (n = 7) and 3.0 ± 0.5 μm (n = 8) after 15 minutes and 2 hours, respectively. CONCLUSIONS Light-adaption induces an increase in the thickness of the outer retina and the appearance of a hyporeflective band in the OCT image. This is consistent with previous reports of light-induced fluid accumulation in the subretinal space.
منابع مشابه
High-speed ultra-high-resolution optical coherence tomography findings in hydroxychloroquine retinopathy.
OBJECTIVES To compare structural changes in the retina seen on high-speed ultra-high-resolution optical coherence tomography (hsUHR-OCT) with multifocal electroretinography (mfERG) and automated visual fields in patients receiving hydroxychloroquine. METHODS Fifteen patients receiving hydroxychloroquine were evaluated clinically with hsUHR-OCT, mfERG, and automated visual fields. Six age-matc...
متن کاملHigh-resolution spectral domain optical coherence tomography and fundus autofluorescence correlation in tubercular serpiginouslike choroiditis
OBJECTIVE This study aims to describe changes in high-resolution spectral domain optical coherence tomography (SD-OCT) scans with simultaneous fundus autoflorescence (FAF) signals in tubercular serpiginouslike choroiditis (SLC). METHODS Simultaneous SD-OCT and FAF imaging of eyes affected with SLC from acute stage until resolution of lesions was obtained using Spectralis HRA+OCT system (Heide...
متن کاملEffect of Hydroxychloroquine on the Retinal Layers: A Quantitative Evaluation with Spectral-Domain Optical Coherence Tomography
Purpose. To evaluate the effect of hydroxychloroquine on retinal pigment epithelium- (RPE-) Bruch's membrane complex, photoreceptor outer segment, and macular ganglion cell-inner plexiform layer (GCIPL) thicknesses using spectral-domain optical coherence tomography (SD-OCT). Methods. In this prospective case-control study, 51 eyes of 51 hydroxychloroquine patients and 30 eyes of 30 healthy subj...
متن کاملStimulus-induced changes of reflectivity detected by optical coherence tomography in macaque retina.
PURPOSE To investigate the properties and origin of retinal intrinsic signals by functional optical coherence tomography (fOCT) in macaque retinas. METHODS We modified a spectral domain OCT system to be able to give short-duration flashes or continuous light stimulation to the retina of three adult macaque monkeys (Macaca mulatta) under general anesthesia. Changes in the intensities of the OC...
متن کاملCharacterization of outer retinal morphology with high-speed, ultrahigh-resolution optical coherence tomography.
PURPOSE To visualize, quantitatively assess, and interpret outer retinal morphology by using high-speed, ultrahigh-resolution (UHR) OCT. METHODS Retinal imaging was performed in the ophthalmic clinic in a cross-section of 43 normal subjects with a 3.5-microm, axial-resolution, high-speed, UHR OCT prototype instrument, using a radial scan pattern (24 images, 1500 axial scans). Outer retinal la...